Products on sale

  • Venus GX

    R5,489.27

  • VE.Direct Cable (side right angle conn) 10m

    R420.68

  • VE.Direct Cable (side right angle conn) 5m

    R347.99

  • VE.Direct Cable (side right angle conn) 3m

    R311.14

Multiplus 12/3000/120/16

R26,603.97

Description

PowerControl Yes
PowerAssist Yes
Transfer switch (A) 50
Parallel and 3-phase operation Yes
INVERTER
Input voltage range (V DC) 9,5 – 17 V 19 – 33 V
Output Output voltage: 120 VAC ± 2% Frequency: 60 Hz ± 0,1% (1)
Cont. output power at 25ºC / 77°F (VA) (3) 3000
Cont. output power at 25ºC / 77°F (W) 2400
Cont. output power at 40ºC / 104°F (W) 2200
Cont. output power at 65ºC / 150°F (W) 1700
Peak power (W) 6000
Maximum efficiency (%) 93 / 94
Zero load power (W) 20 / 20
Zero load power in AES mode (W) 15 / 15
Zero load power in Search mode (W) 8 / 10
CHARGER
AC Input Input voltage range: 95-140 VAC Input frequency: 45 – 65 Hz Power factor: 1
Charge voltage ‘absorption’ (V DC) 14,4 / 28,8
Charge voltage ‘float’ (V DC) 13,8 / 27,6
Storage mode (V DC) 13,2 / 26,4
Charge current house battery (A) (4) 120 / 70
Charge current starter battery (A) 4
Battery temperature sensor yes
GENERAL
Auxiliary output (5) n. a. Yes (32A)
Programmable relay (6) Yes (1x) Yes (3x)
Protection (2) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
General purpose com. port (7)Yes (2x)
Remote on-off Yes
Common Characteristics Operating temp. range: -40 – +65°C / -40 to 150°F (fan assisted cooling) Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21
Battery-connection M8 bolts (2 plus and 2 minus connections)
120 V AC-connection Screw-terminal 6 AWG (13mm²)
Weight . 19kg 40 lbs.
Dimensions (hxwxd in mm and inches) 362x258x218 mm 14.3×10.2×8.6 inch
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 55014-2, EN 61000-3-3
1) Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 VAC on inverter output
g) input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 75˚F ambient
5) Switches off when no external AC source available
6) Programmable relay that can a.o. be set for general
alarm,
DC under voltage or genset start/stop function
AC rating: 230 V/4 A
DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC
7) A.o. to communicate with a Lithium Ion battery BMS

Additional information

Weight 19 kg
Dimensions 36.2 × 25.8 × 21.8 cm

Reviews

There are no reviews yet.

Be the first to review “Multiplus 12/3000/120/16”

Related products

  • Venus GX

    R5,489.27

  • VE.Direct Cable (side right angle conn) 10m

    R420.68

  • VE.Direct Cable (side right angle conn) 5m

    R347.99

  • VE.Direct Cable (side right angle conn) 3m

    R311.14

Title

Go to Top