Description
Cont. power at 25 degree celcius(1): 500VA
Cont. power at 25/40 degree celcuis: 400/350W
Peak power: 900W
Output AC voltage/frequency(adjustable): 230VAC or 120VAC +/-3% 50Hz or 60Hz +-.01%
Input voltage range: 9,2-17/18,4-34,0/36,8-62,0V
DC low shut down(adjustable): 9,3/18,6/37,2V
Dynamic(load dependant) DC low shut down(fully configurable): https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff
DC low restart and alarm(adjustable): 10,9/21,8/43,6V
Battery charged detect(adjustable): 14,0/28,0/56,0V
Max efficiency: 90/90/91%
Zero-load power: 6/6.5/7,9W
Default zero-load power in ECO mode(default retry interval:2,5s,adjustable: 1/1,5/3,0W
ECO mode stop and start power setting: Adjustable
Protection(2): a-f
Operating temperature range: -40 to +65 degree celcius(fan assisted cooling) Derate 1,25% per degree celcuis above 40 degree celsius
Humidity(non-condensing) max 95%
Enclosure:
Material & Colour: Steel chassis and plastic cover (blue Ral 5012)
Battery-connection: Screw terminals
Maximuim cable cross section: 10mm2 / AWG8
Standard AC outlets: 230V: Schuko(CEE 7/4). IEC-320(male plug included) UK(BS 1363), AU/NZ (AS/NZS 3112) 120V:Nema 5-15R
Protection category: IP21
Weight: 3,9kg/8,5lbs
Dimensions(mm) 86x172x275
Accessries:
Remote on-off: Yes
Automatic transfer switch: Filax
Standards:
Safety: EN-IEC 60335-1 / EN-IEC 62109-1
EMC: EN 55014-1/ EN55014-2 / IEC6100-6-1 / IEC6100-6-2 / IEC6100-6-3
Automatic Directive: ECE R10-4
- Nonlinear load, crest factor 3:1
- Protection key:
- a) output short circuit
- b) overload
- c) battery voltage too high
- d) battery voltage too low
- e) temperature too high
- f) DC ripple too high