VICTRON PHOENIX COMPACT 12/1200 INVERTER
R11,582.41
Description
Parallel and 3-phase operation Yes
INVERTER
Input voltage range (V DC) 9,5 – 17V 19 – 33V 38 – 66V
Output Output voltage: 230 VAC ±2% Frequency: 50 Hz ± 0,1% (1)
Cont. output power at 25ºC (VA) (2) 1200
Cont. output power at 25ºC (W) 1000
Cont. output power at 40ºC (W) 900
Cont. output power at 65ºC (W) 600
Peak power (W) 2400
Max. efficiency 12/ 24 /48 V (%) 92 / 94 / 94
Zero load power 12 / 24 / 48 V (W) 8 / 10 / 12
Zero load power in AES mode (W) 5 / 8 / 10
Zero load power in Search mode (W) 2 / 3 / 4
GENERAL
Programmable relay (3) Yes
Protection (4) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
Remote on-off Yes
Common Characteristics Operating temperature range: -40 to +65ºC (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21
Battery-connection battery cables of 1.5 meter included
230 V AC-connection G-ST18i plug
Weight (kg) 10
Dimensions (hxwhd in mm) 375x214x110
STANDARDS
Safety EN 60335-1
Emission Immunity EN 55014-1 / EN 55014-2
1) Can be adjusted to 60 Hz and to 240 V
2) Non-linear load, crest factor 3:1
3) Programmable relay that can a.o. be set for
general alarm, DC under voltage or genset
start/stop function.
AC rating: 230 V / 4 A
DC rating: 4 A up to 35 VDC, 1A up to
60VDC
4) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 V AC on inverter output
g) input voltage ripple too high
Additional information