  • VE.Direct Cable (side right angle conn) 3m

    R311.14

    View product
  • Multiplus 24/800/16-16

    R9,014.24

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • VE.Direct Cable (side right angle conn) 10m

    R420.68

    View product
  • 8 Way Distribution Box IP65 Surface Mount DIN PVC

    R240.60

    View product
  • 1 String DC PV Input Combiner Box – 1 DC Output

    DC combiner boxes are for connecting parallel PV strings into your MPPT. The box includes several features that reduces the amount of separate components you need to install.

    The box offers isolation between the DC voltages that are generated by the PV modules and the solar installation allowing for safety while working or maintaining the system.
    With fusing and short circuit protection the PV modules and components can operate optimally with lightning protection included. Combining multiple series strings from the PV modules the unit allows for a single parallel connection to the MPPT charge controller.
    Positive and negative poles of each PV string are equipped with special fuse wire, which protects the PV string from fault. It also uses matchable fuse holder and fuse wire to reduce later maintenance cost and guarantee safety
    The unit uses photovoltaic HV lightning protector to carry out protection to the positive pole-to-ground and negative pole-to-ground of bus after combination

    View product
  • Multiplus 48/500/6-16

    R7,195.27

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • MultiPlus-II 48/5000/70-50

    R15,434.15

    53% Off

    A MultiPlus, plus ESS (Energy Storage System) functionality
    The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
    currentsensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
    The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
    It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
    Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
    PowerControl and PowerAssist – Boosting the capacity of the grid or a generator
    A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
    whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
    function).
    PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
    limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
    When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
    compatible with both solar charger controllers and grid-tie inverters.
    Two AC Outputs
    The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
    a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
    battery, like a water heater for example, can be connected to this output.
    Virtually unlimited power thanks to parallel and three phase operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
    25 kW / 30 kVA output power with 420 Amps charging capacity.
    In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
    all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
    capacity.
    On-site system configuring, monitoring and control
    Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
    needed).
    Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer,
    Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
    Remote configuring and monitoring
    Install a Color Control GX or other GX product to connect to the internet.
    Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    When connected to the internet, systems can be accessed remotely, and settings can be changed.

    View product
  • VE.Direct Cable (side right angle conn) 1.8m

    R316.25

    View product
  • Blue Smart IP22 Charger 24V, 1 output 12A

    R2,982.58

    Input voltage range 180 – 265 VAC

    Charge current, normal mode 12A

    Charge current, NIGHT or LOW 4 / 6 / 8 A

    Efficiency 94%

    No load power consumption 0.5 W

    Frequency 45 – 65 Hz

    Number of outputs 1

    Charge voltage ‘absorption’ Normal: 28,8V High: 29,4V Li-ion: 28,4V

    Charge voltage ‘float’ Normal: 27,6V High: 27,6V Li-ion: 27,0V

    Charge voltage ‘storage Normal: 26,4V High: 26,4V Li-ion: 27,0V

    Charge algorithm 6-stage adaptive

    Can be used as power supply Yes

    Protection Battery reverse polarity (fuse) Output short circuit Over temperature

    Operating temp. range -20 to +50°C

    Humidity (non-condensing) Max 98%

     

    ENCLOSURE

    Material & Colour Aluminium (blue RAL 5012)

    Battery connection Screw terminals 13 mm² / AWG6

    230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)

    Protection category IP22

    Weight 1,3 kg

    Dimensions (h x w x d) 235 x 108 x 65 mm

     

    STANDARDS

    Safety EN 60335-1, EN 60335-2-29

    Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2

    Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3

    Automotive E4-10R

    View product
  • REVOV 2nd LiFe 200Ah 10.2kWh LiFePO4 Battery

    LiFePO4 chemistry is considered very safe even if
    fully charged.
    • Reliability – battery designed to operate in almost
    any environment.
    • Durability – life expectancy exceeding 10 years
    at 25oC.
    • Supports parallel bus bar connection.
    • External BMS.
    • Manufacturing plants comply with the
    legislation in each country and with
    international quality standards ISO9001 and
    Qs9000.
    • Residential, Business, Factory, Data Centres or
    Telecoms Base Station backup.
    • Solar, Wind or Hybrid Storage.
    • Reduce Peak Usage Charges from the Grid

     

    View product
  • Deye 10kw Single Phase Hybrid Inverter

    R30,417.50

    11% Off

    View product
  • 12 Way Distribution Box IP65 Surface Mount DIN PVC

    R347.52

    View product

Urna elit, sem lobortis faucibus facilisi vel lectus etiam phasellus odio.

Urna elit, sem lobortis faucibus facilisi vel lectus etiam phasellus odio.

Urna elit, sem lobortis faucibus facilisi vel lectus etiam phasellus odio.

Shop men

Morbi leo sagittis placerat sem. Nisl tincidunt nulla fames nisl risus egestas.

Morbi leo sagittis placerat sem. Nisl tincidunt nulla fames nisl risus egestas.

Shop streetwear

Morbi leo sagittis placerat sem. Nisl tincidunt nulla fames nisl risus egestas.

Shop women

Morbi leo sagittis placerat sem. Nisl tincidunt nulla fames nisl risus egestas.

Subscribe to our newsletter and get 10% Off!

Velit morbi sed non est dolor tellus fringilla diam

Title

Go to Top