EasySolar 24/1600/40-16 MPPT 100/50

R25,250.12

Description

Transfer switch 16A
INVERTER
Input voltage range 19 – 33V
‘Heavy duty’ output AC 16 A
Output AC1, 2, 3 Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1% (1)
Cont. output power at 25°C (3) 1600VA / 1300W
Cont. output power at 40°C 1200W
Peak power 3000W
Maximum efficiency 94%
Zero load power 10W
Zero load power in search mode 3W
CHARGER
AC Input Input voltage range: 187-265 VAC
Input frequency: 45 – 65 Hz Power factor: 1
Charge voltage ‘absorption’ 28,8V
Charge voltage ‘float’ 27,6V
Storage mode 26,4V
Charge current house battery (4) 40A
Charge current starter battery (A) 4
Battery temperature sensor yes
Programmable relay (5) yes
Protection (2) a – g
Solar Charge Controller
Model MPPT 100/50
Maximum output current 50 A
Maximum PV power, 6a,b) 1400W
Maximum PV open circuit voltage 100V
Maximum efficiency 98%
Self-consumption 10 mA
Charge voltage ‘absorption’, default setting 28,8V
Charge voltage ‘float’, default setting 27,6V
Charge algorithm multi-stage adaptive
Temperature compensation -32 mV / °C
Protection a – g
COMMON CHARACTERISTICS
Operating temp. range -20 to +50°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE

Material & Colour aluminium (blue RAL 5012)
Protection category IP 21
Battery-connection Battery cables of 1.5 meter
PV connection Three sets of MC4 (PV-ST01) PV connectors.
230 V AC-connection G-ST18i connector
Weight 15kg
Dimensions (hxwxd) 745 x 214 x 110mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29, EN 62109
Emission / Immunity EN 55014-1, EN 55014-2, EN 61000-3-3
Automotive Directive 2004/104/EC
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230 VAC on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for general alarm, DC under
voltage or genset start signal function
6a) If more PV power is connected, the controller will limit input power to
700 W resp. 1400 W
6b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V

Additional information

Weight 15 kg
Dimensions 74.5 × 21.4 × 11 cm

Reviews