Products on sale

  • Venus GX

    R5,489.27

  • VE.Direct Cable (side right angle conn) 10m

    R420.68

  • VE.Direct Cable (side right angle conn) 5m

    R347.99

  • VE.Direct Cable (side right angle conn) 3m

    R311.14

Multiplus 12/1200/50-16

R12,990.84

Description

PowerControl / PowerAssist Yes
Three Phase and parallel operation Yes
Transfer switch 16A
INVERTER
Input voltage range 9,5 – 17V 19 – 33V 38– 66V
Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
Cont. output power at 25°C (3) 1200VA
Cont. output power at 25°C 1000W
Cont. output power at 40°C 900W
Cont. output power at 65°C 600W
Peak power 2400W
Maximum efficiency 93 / 94 / 95%
Zero-load power 10 / 9 / 10W
Zero-load power in search mode 3/ 3 / 3W
CHARGER
AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
Charge voltage ‘absorption’ 14,4 / 28,8 / 57,6V
Charge voltage ‘float’ 13,8 / 27,6 / 55,2V
Storage mode 13,2 / 26,4 /52,8V
Charge current house battery (4) 50 / 25 / 13A
Charge current starter battery 1A (12V and 24V models only)
Battery temperature sensor Yes
GENERAL
Programmable relay (5) Yes
Protection (2) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
(RJ45-spliter ASS030065510 needed for 500/800/12ooVA models)
Remote on-off On/off/charger only On/off
DIP switches Yes (6) Yes (3)
Internal DC fuse 200/100/50A
Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
Battery-connection 35 / 25 / 10 mm²
230V AC-connection G-ST18i connector
Weight 8,2 kg
Dimensions (h x w x d) 406 x 250 x 100 mm
STANDARDS
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles ECE R10-5
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for:
general alarm, DC under voltage or generator start/stop signal function
AC rating: 230V/4A
DC rating: 4A up to 35VDC, 1A up to 60VDC

Additional information

Weight 8.2 kg
Dimensions 40.6 × 25 × 10 cm

Reviews

There are no reviews yet.

Be the first to review “Multiplus 12/1200/50-16”

Related products

  • Venus GX

    R5,489.27

  • VE.Direct Cable (side right angle conn) 10m

    R420.68

  • VE.Direct Cable (side right angle conn) 5m

    R347.99

  • VE.Direct Cable (side right angle conn) 3m

    R311.14

Title

Go to Top