Multiplus 12/800/35-16

0 out of 5

R9,313.24

Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connect

Compare

Description

PowerControl / PowerAssist Yes
Three Phase and parallel operation Yes
Transfer switch 16A
INVERTER
Input voltage range 9,5 – 17V 19 – 33V 38– 66V
Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
Cont. output power at 25°C (3) 800VA
Cont. output power at 25°C 700W
Cont. output power at 40°C 650W
Cont. output power at 65°C 400W
Peak power 1600W
Maximum efficiency 92 / 93 / 94%
Zero-load power 7 / 7 / 8W
Zero-load power in search mode 2 / 2 / 3W
CHARGER
AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
Charge voltage ‘absorption’ 14,4 / 28,8 / 57,6V
Charge voltage ‘float’ 13,8 / 27,6 / 55,2V
Storage mode 13,2 / 26,4 /52,8V
Charge current house battery (4) 35 / 16 / 9A
Charge current starter battery 1A (12V and 24V models only)
Battery temperature sensor Yes
GENERAL
Programmable relay (5) Yes
Protection (2) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
(RJ45-spliter ASS030065510 needed for 500/800/12ooVA models)
Remote on-off On/off/charger only On/off
DIP switches Yes (6) Yes (3)
Internal DC fuse 150/80/40A
Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
Battery-connection 25 / 16 / 10 mm²
230V AC-connection G-ST18i connector
Weight 6,4 kg
Dimensions (h x w x d) 360 x 240 x 100 mm
STANDARDS
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles ECE R10-5
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for:
general alarm, DC under voltage or generator start/stop signal function
AC rating: 230V/4A
DC rating: 4A up to 35VDC, 1A up to 60VDC

Additional information

Weight 6.4 kg
Dimensions 36 × 24 × 10 cm

Reviews

There are no reviews yet.

Be the first to review “Multiplus 12/800/35-16”