Quattro 24/3000/70-50/50
R38,423.87
Description
PowerControl / PowerAssist Yes
Integrated Transfer switch Yes
AC inputs (2x) Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1
Maximum feed through current (A) 2x 50 2
INVERTER
Input voltage range (V DC) 9,5 – 17V 19 – 33V 38 – 66V
Output (1) Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1%
Cont. output power at 25°C (VA) (3) 3000
Cont. output power at 25°C (W) 2400
Cont. output power at 40°C (W) 2200
Cont. output power at 65°C (W) 1700
Peak power (W) 6000
Maximum efficiency (%) 93 / 94
Zero load power (W) 20 / 20
Zero load power in AES mode (W) 15 / 15
Zero load power in Search mode (W) 8 / 10
CHARGER
Charge voltage ‘absorption’ (V DC) 14,4 / 28,8
Charge voltage ‘float’ (V DC) 13,8 / 27,6
Storage mode (V DC) 13,2 / 26,4
Charge current house battery (A) (4) 120 / 70
Charge current starter battery (A) 4 (12V and 24V models only)
Battery temperature sensor Yes
GENERAL
Auxiliary output (A) (5) 25
Programmable relay (6) 3x
Protection (2) a-g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
General purpose com. port 2x
Remote on-off Yes
Common Characteristics Operating temp.: -40 to +65˚C Humidity (non-condensing): max. 95%
ENCLOSURE
Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21
Battery-connection Four M8 bolts (2 plus and 2 minus connections)
230 V AC-connection Screw terminals 13 mm2
Weight (kg) 19
Dimensions (hxwxd in mm) 362 x 258 x 218
STANDARDS
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1
Emission, Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles 12V and 24V models: ECE R10-4
Anti-islanding See our website
1) Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 VAC on inverter output
g) input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25˚C ambient
5) Switches off when no external AC source available
6) Programmable relay that can a.o. be set for general alarm,
DC under voltage or genset start/stop function
AC rating: 230 V / 4 A
DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC
Additional information
Weight | 19 kg |
---|---|
Dimensions | 36.2 × 25.8 × 21.8 cm |
You must be logged in to post a review.