Blue Smart IP67 Charger 24/5
R1,947.41
21% Off
Input voltage range and frequency 180-265 VAC 45-65 Hz
Efficiency 94%
No load power consumption 0.5W
Charge voltage ‘absorption’ Normal: 28,8V
High: 29,4V
Li-ion: 28,4V
Charge voltage ‘float’ Normal: 27,6V
High: 27,6V
Li-ion: 27,0V
Charge voltage ‘storage’ Normal: 26,4V
High: 26,4V
Li-ion: 27,0V
Charge current, normal mode 5A
Charge current, LOW 2A
Charge algorithm 5-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +60°C (full rated output up to 40°C) Derate 3% per °C above 40°C
Humidity Up to 100%
Start interrupt option (Si) Short circuit proof, current limit 0,5 A
(12/25 and 24/12 models only) Output voltage: max one volt lower than main output
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with CEE 7/7 plug
Protection category IP67
Weight (kg) 1,8
Dimensions (h x w x d in mm) 85 x 211 x 60
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-6-3, EN 61000-3-2
Automotive Directive EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Geyserwise 150L PV Waterheating System Installed With COC
The system makes use of photovoltaic technology and a unique PTC AC/DC element to heat the water
in the geyser. This differs from the traditional thermal hot water systems where water is cycled from a
collector through pipes to the hot water cylinder by either making use of a 220V pump, 12V pump or
thermo siphoning.
Advantages over thermal hot water systems are as follows:
Any existing geyser can be converted
No Additional plumbing is required
No pumps necessary to circulate water
No risk of damaged panels in frost prone areas
The water temperature can be controlled on very hot summer days – reduced risk of overheating
problems
Suitable in all water conditions
Suitable in areas where the geyser is not situated near the panels
Modular system – can be expanded to build off-grid power system for the homeVictron Energy SmartSolar MPPT 100 | 50 controler
R3,289.00
46% Off
The smart solar 100/50 is designed to accept solar panel (PV) input up to 700W at 12V or 1400W at 24V and has a rated charge current of 50A.
However, you should note both the open circuit voltage (Voc) and the short circuit current (Isc) of your combined solar panels and ensure this does not exceed the maximum input of the MPPT charge controller. For the 100/50 the maximum PV open circuit voltage (Voc) is 100V and the maximum PV short circuit current (Isc) is 60A.
Auto-selects 12/24V on the output. The charge controller once connected will automatically recognise your battery bank voltage.
Bluetooth Monitoring built-in. Remotely control and monitor the extensive features of your SmartSolar MPPT charge controller with built-in bluetooth by pairing it with your smartphone or tablet via the VictronConnect app. (Bluetooth dongle not required
Blue Smart IP65 Charger 24 V 8A
R2,734.59
Input voltage 230 VAC
Efficiency 95%
Standby power consumption 0,5 W
Minimum battery voltage Starts charging from down to 0V
Charge voltage ‘absorption’ Normal: 28,8 V
High: 29,4 V
Li-ion: 28,4 V
Charge voltage ‘float’ Normal: 27,6 V
High: 27,6 V
Li-ion: 27,0 V
Charge voltage ‘storage’ Normal: 26,4 V
High: 26,4 V
Li-ion: 27,0 V
Charge current 8A
Low current mode 3A
Temperature compensation 32 mV/ºC
(lead-acid batteries only)
Can be used as power supply Yes
Back current drain 0,7 Ah/month (1 mA)
Protection Reverse polarity Output short circuit
Over temperature
Operating temp. range -40 to +60°C (full rated output up to 30°C)
(cables retain flexibility at low temperature)
Humidity (non-condensing) Max 95%
ENCLOSURE
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with
CEE 7/7, BS 1363 plug (UK) or AS/NZS 3112 plug
Protection category IP65 (splash and dust proof)
Weight IP65 12V 25A 24V 13A: 1,9kg
Other: 0,9kg
Dimensions (h x w x d) 24V 8A: 60x105x190mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2,EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Multiplus 12/1200/50-16
R12,990.84
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connect
Shop Grid – 3 ColumnsMarketing2021-03-01T16:11:38+02:00