Multiplus 48/800/9-16
R9,807.59
PowerControl / PowerAssist Yes
Three Phase and parallel operation Yes
Transfer switch 16A
INVERTER
Input voltage range 9,5 – 17V 19 – 33V 38– 66V
Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
Cont. output power at 25°C (3) 800VA
Cont. output power at 25°C 700W
Cont. output power at 40°C 650W
Cont. output power at 65°C 400W
Peak power 1600W
Maximum efficiency 92 / 93 / 94%
Zero-load power 7 / 7 / 8W
Zero-load power in search mode 2 / 2 / 3W
CHARGER
AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
Charge voltage ‘absorption’ 14,4 / 28,8 / 57,6V
Charge voltage ‘float’ 13,8 / 27,6 / 55,2V
Storage mode 13,2 / 26,4 /52,8V
Charge current house battery (4) 35 / 16 / 9A
Charge current starter battery 1A (12V and 24V models only)
Battery temperature sensor Yes
GENERAL
Programmable relay (5) Yes
Protection (2) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
(RJ45-spliter ASS030065510 needed for 500/800/12ooVA models)
Remote on-off On/off/charger only On/off
DIP switches Yes (6) Yes (3)
Internal DC fuse 150/80/40A
Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
Battery-connection 25 / 16 / 10 mm²
230V AC-connection G-ST18i connector
Weight 6,4 kg
Dimensions (h x w x d) 360 x 240 x 100 mm
STANDARDS
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles ECE R10-5
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for:
general alarm, DC under voltage or generator start/stop signal function
AC rating: 230V/4A
DC rating: 4A up to 35VDC, 1A up to 60VDCBlue Smart IP67 Charger12/7
R1,760.65
8% Off
Input voltage range and frequency 180-265 VAC 45-65 Hz
Efficiency 93%
No load power consumption 0.5W
Charge voltage ‘absorption’ Normal: 14,4V
High: 14,7V
Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V
High: 13,8V
Li-ion: 13,5V
Charge voltage ‘storage’ Normal: 13,2V
High: 13,2V
Li-ion: 13,5V
Charge current, normal mode 7A
Charge current, LOW 2A
Charge algorithm 5-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +60°C (full rated output up to 40°C) Derate 3% per °C above 40°C
Humidity Up to 100%
Start interrupt option (Si) Short circuit proof, current limit 0,5 A
(12/25 and 24/12 models only) Output voltage: max one volt lower than main output
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with CEE 7/7 plug
Protection category IP67
Weight (kg) 1,8
Dimensions (h x w x d in mm) 85 x 211 x 60
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-6-3, EN 61000-3-2
Automotive Directive EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
VICTRON BLUESOLAR MPPT 75/10 10 AMP SOLAR CHARGE CONTROLLER REGULATOR
R956.19
35% Off
Victron Blue Solar MPPT 75/10 10 Amp (12V/24V) Solar Charge Controller Regulator is the perfect choice for the heavy load projects. The Victron Blue Solar MPPT 75/10 10 Amp (12V/24V) Solar Charge Controller Regulator has a variety of features that ensures you get the best performance from your Solar Panels through to your batteries.
Color Control GX
All Victron Energy MPPT Charge Controllers are compatible with the Color Control GX: The Color Control GX provides intuitive control and monitoring for all products connected to it. The list of Victron products that can be connected is endless: Inverters, Multis, Quattros, MPPT 150/70, BMV-600 series, BMV-700 series, Skylla-i, Lynx Ion and even more.
VRM Online Portal
Besides monitoring and controlling products on the Color Control GX, the information is also forwarded to our free remote monitoring website: the VRM Online Portal. The portal is free of charge.
Related product:EasySolar Minimal wiring and an all-in-one solution: the EasySolar takes power solutions one stage further, by combining an Ultra BlueSolar charge controller (MPPT), an inverter/charger and AC distribution in one enclosure.
Victron Blue Solar MPPT 75/10 10 Amp (12V/24V) Amp Solar Charge Controller Regulator
Ultra-fast Maximum Power Point Tracking (MPPT)Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.
Load outputOver-discharge of the battery can be prevented by connecting all loads to the load output. The load output will disconnect the load when the battery has been discharged to a pre-set voltage. Alternatively, an intelligent battery management algorithm can be chosen: see Battery Life. The load output is short circuit proof. Some loads (especially inverters) can best be connected directly to the battery, and the inverter remote control connected to the load output. A special interface cable may be needed, please see the manual
Battery Life: intelligent battery managementWhen a solar charge controller is not able to recharge the battery to its full capacity within one day, the result is often that the battery will continually be cycled between a ‘partially charged’ state and the ‘end of discharge’ state. This mode of operation (no regular full recharge) will destroy a lead-acid battery within weeks or months. The Battery Life algorithm will monitor the state of charge of the battery and, if needed, day by day slightly increase the load disconnect level (i.e. disconnect the load earlier) until the harvested solar energy is sufficient to recharge the battery to nearly the full 100%. From that point onwards the load disconnect level will be modulated so that a nearly 100% recharge is achieved about once every week.
Programmable battery charge algorithmSee the software section on our website for details
Day/night timing and light dimming optionSee the software section on our website for details
Programming, real-time data and history display options– Modern Apple and Android smartphones, tablets, macbooks and other devices: see the VE.Direct Bluetooth Smart dongle an and the MPPT app discovery sheet for screenshots.
– ColorControl panel
**Note: Phone or Tablet Programming, real-time data and history display options as seen in photos require VE.Direct Bluetooth Dongle available in our Store as Optional Extra
Blue Smart IP67 Charger 24/12
R3,532.11
Input voltage range and frequency 180-265 VAC 45-65 Hz
Efficiency 96%
No load power consumption 0.5W
Charge voltage ‘absorption’ Normal: 28,8V
High: 29,4V
Li-ion: 28,4V
Charge voltage ‘float’ Normal: 27,6V
High: 27,6V
Li-ion: 27,0V
Charge voltage ‘storage’ Normal: 26,4V
High: 26,4V
Li-ion: 27,0V
Charge current, normal mode 12A
Charge current, LOW 4A
Charge algorithm 5-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +60°C (full rated output up to 40°C) Derate 3% per °C above 40°C
Humidity Up to 100%
Start interrupt option (Si) Short circuit proof, current limit 0,5 A
(12/25 and 24/12 models only) Output voltage: max one volt lower than main output
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with CEE 7/7 plug
Protection category IP67
Weight (kg) 2,4
Dimensions (h x w x d in mm) 99 x 219 x 65
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-6-3, EN 61000-3-2
Automotive Directive EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
8L Stainless Steel Gas Geyser – Natural Gas
The Dewhot’ Stainless Steel Slim Line 8L Gas Water Heater.
It is suitable for an out building shower with basin, camping (and) off road trailer and for a hairdresser providing continuous hot water.
TYPE D
For outdoor use under a cover with a flueFeatures
- Requires no electricity – flame ignition and geyser function are battery operated
- 84% energy efficiency
- Neat and compact
- Stainless steel cover
- LCD temperature display
- Flame failure safety device
- Anti-freeze function
MultiPlus-II 48/5000/70-50
R15,434.15
53% Off
A MultiPlus, plus ESS (Energy Storage System) functionality
The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
currentsensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
PowerControl and PowerAssist – Boosting the capacity of the grid or a generator
A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
compatible with both solar charger controllers and grid-tie inverters.
Two AC Outputs
The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel and three phase operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
25 kW / 30 kVA output power with 420 Amps charging capacity.
In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
capacity.
On-site system configuring, monitoring and control
Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
needed).
Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer,
Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
Remote configuring and monitoring
Install a Color Control GX or other GX product to connect to the internet.
Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
When connected to the internet, systems can be accessed remotely, and settings can be changed.XPE+COB 2Lights 1800Lumens 3Modes USB Rechargeable Brightness EDC LED Flashlight Suit
R75.00
Features:
1. Small size,convenient for everyday carry.Specially designed for hiking.camping and emergency use
2. Brightness level. With max output of 1800 lumens.
3. Max beam distance up to 100 meters.
4. Effective power management circuit.
5. Battery reverse protection function
6.1 meter impact resistant.
7.Specially 2 lights designed:XPE LED for front light, COB LED for side light.Package included:
1 x XANES 1517 XPE+COB 1800Lumens 4Modes Brightness EDC Tactical LED Flashlight
1 x Lanyard1 x USB Cable
Quattro 12/3000/120-50/50
R30,115.97
26% Off
Two AC inputs with integrated transfer switch
The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
the battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel operation
Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
power and 840 Amps charging capacity.
Split phase options
Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30kW / 36kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
Three phase capability
Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
being overloaded.
PowerAssist – Boosting shore or generator power
This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
be changed remotelyBlueSolar PWM-Light Charge Controller 12/24V-5A
R410.09
BlueSolar PWM-Light 12/24V-5A
Victron Bluesolar light PWM solar controller:
Victron’s range of PWM and MPPT charge controllers are both widely used to charge batteries with solar power.The PWM controller is in essence a switch that connects a solar array to the battery. The result is that the voltage of the array will be pulled down to near that of the battery.
A PWM controller is not a DC to DC transformer. The PWM controller is a switch which connects the solar panel to the battery. When the switch is closed, the panel and the battery will be at nearly the same voltage. Assuming a discharged battery the initial charge voltage will be around 13 V, and assuming a voltage loss of 0,5 V over the cabling plus controller, the panel will be at Vpwm = 13,5 V.
The voltage will slowly increase with increasing state of charge of the battery. When absorption voltage is reached the PWM controller will start to disconnect and reconnect the panel to prevent overcharge (hence the name: Pulse Width Modulated controller).
Features:
– Load output with low battery voltage disconnect function.
– Lighting control function, one timer only.
– Two digit seven segment display for quick and easy setting of the load output functionality, including timer setting.
– Three stage battery charging (bulk, absorption, float), not programmable.
– Load output protected against over load and short circuit.
– Protected against reverse polarity connection of the solar array and/or battery.
Day/night timing options: