REVOV 2nd LiFe 200Ah 10.2kWh LiFePO4 Battery
LiFePO4 chemistry is considered very safe even if
fully charged.
• Reliability – battery designed to operate in almost
any environment.
• Durability – life expectancy exceeding 10 years
at 25oC.
• Supports parallel bus bar connection.
• External BMS.
• Manufacturing plants comply with the
legislation in each country and with
international quality standards ISO9001 and
Qs9000.
• Residential, Business, Factory, Data Centres or
Telecoms Base Station backup.
• Solar, Wind or Hybrid Storage.
• Reduce Peak Usage Charges from the Grid30A PWM SOLAR CHARGE CONTROLLER 12/24V With Digital Display
R586.50
Specifications :
Size : 14 x 7.6 x 4cm
Package weight : 6.3oz/178g
Rated voltage : 12V / 24V
Voltage of ending power supply : 10.8V
Recovery voltage of power supply : 10.8V
Voltage of ending charging : 14.7V or 29.4V
Rated charging current : 30A
DC output voltage : 12V or 24V
DC output current : 1A
Rated load current : 30AMultiPlus-II 48/5000/70-50
R15,434.15
53% Off
A MultiPlus, plus ESS (Energy Storage System) functionality
The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
currentsensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
PowerControl and PowerAssist – Boosting the capacity of the grid or a generator
A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
compatible with both solar charger controllers and grid-tie inverters.
Two AC Outputs
The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel and three phase operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
25 kW / 30 kVA output power with 420 Amps charging capacity.
In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
capacity.
On-site system configuring, monitoring and control
Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
needed).
Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer,
Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
Remote configuring and monitoring
Install a Color Control GX or other GX product to connect to the internet.
Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
When connected to the internet, systems can be accessed remotely, and settings can be changed.20L Room Sealed Fan Forced Gas Geyser (RS20)
Shipped with a Free Flexi Flue
Multiple use application geyser (run multiple outlets simultaneously)
The cutting edge RS20 is equipped with many unique features and is constructed out of high quality components. Versatile and compact, the RS20 is one of the safest and most efficient gas water heaters on the market.
TYPE C
For outdoor use under a cover with shortened flue or indoor use with a flueFeatures
- Heavy duty copper radiator
- 88% energy efficiency
- Can be installed in confined and unventilated spaces
- Wind resistent burner
- Anti-freeze function
- Touch button temperature control
- Compatible with mixer taps
- Ensures constant temperature when multiple outlets are used simultaneously
- Compact design with a brushed aluminum cover
- Flame failure safety device
- Inverter compatible
Multiplus 24/5000/120-100
R33,826.79
21% Off
Multifunctional, with intelligent power management
The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge
technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the
MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of
a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output (second output available on models rated at
3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide
15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three
strings of six parallel units a 45 kW / 54 kVA three phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30 kW / 36 kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore
current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus
preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will
make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software.
The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage
for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger
datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second
battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go.
If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even
parallel and 3-phase operation can be programmed with DIP switches: no computer needed!
Alternatively, VE.Net can be used instead of the DIP switches.
And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several
new, advanced, features8L Eco-Dew Gas Geyser
The 8l Dewhot Ecodew white powder coated gas water heater is suitable for a shower and wash hand basin application. It will also be ideal for camping, off road trailers and hairdressing salons providing continuous hot water. This unit is suitable for outdoor installation only.
TYPE D
For outdoor use under a cover with a flue.Features
- Requires no electricity – flame ignition and geyser function are battery operated
- 84% energy efficiency
- Neat and compact
- Stainless steel cover
- LCD temperature display
- Flame failure safety device
- Anti-freeze function
Victron Energy BlueSolar MPPT Charge Controller 150/70 Tr
R5,925.26
49% Off
BlueSolar MPPT 150/35 (12/24/48V – 70A)
Ultra-fast Maximum Power Point Tracking (MPPT)
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT Controller will improve energy harvest by up to 30% compared to PWM Charge Controllers and by up to 10% compared to slower MPPT Controllers.Feature Highlights
- Ultra-fast Maximum Power Point Tracking (MPPT)
- Advanced Maximum Power Point Detection in case of partial shading conditions
- Load output on the small models
- BatteryLife: intelligent battery management by load shedding
- Automatic battery voltage recognition
- Flexible charge algorithm
- Over-temperature protection and power de-rating when temperature is high
All Victron Energy MPPT Charge Controllers are compatible with the Color Control GX: The Color Control GX provides intuitive control and monitoring for all products connected to it. The list of Victron products that can be connected is endless: Inverters, Multis, Quattros, MPPT 150/70, BMV-600 series, BMV-700 series, Skylla-i, Lynx Ion and even more.
Shop Grid – 3 ColumnsMarketing2021-03-01T16:11:38+02:00