Blue Smart IP22 Charger 24V, 1 output 16A
R3,568.06
Input voltage range 180 – 265 VAC
Charge current, normal mode 16A
Charge current, NIGHT or LOW 4 / 6 / 8 A
Efficiency 94%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 1
Charge voltage ‘absorption’ Normal: 28,8V High: 29,4V Li-ion: 28,4V
Charge voltage ‘float’ Normal: 27,6V High: 27,6V Li-ion: 27,0V
Charge voltage ‘storage Normal: 26,4V High: 26,4V Li-ion: 27,0V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
Blue Smart IP22 Charger 24V, 1 output 12A
R2,982.58
Input voltage range 180 – 265 VAC
Charge current, normal mode 12A
Charge current, NIGHT or LOW 4 / 6 / 8 A
Efficiency 94%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 1
Charge voltage ‘absorption’ Normal: 28,8V High: 29,4V Li-ion: 28,4V
Charge voltage ‘float’ Normal: 27,6V High: 27,6V Li-ion: 27,0V
Charge voltage ‘storage Normal: 26,4V High: 26,4V Li-ion: 27,0V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
Blue Smart IP22 Charger 24V, 1 output 8A
R2,433.98
Input voltage range 180 – 265 VAC
Charge current, normal mode 8A
Charge current, NIGHT or LOW 4 / 6 / 8 A
Efficiency 94%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 1
Charge voltage ‘absorption’ Normal: 28,8V High: 29,4V Li-ion: 28,4V
Charge voltage ‘float’ Normal: 27,6V High: 27,6V Li-ion: 27,0V
Charge voltage ‘storage Normal: 26,4V High: 26,4V Li-ion: 27,0V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
BlueSmart IP22 Charger 12/30(3) 230V CEE 7/7
R3,951.92
Input voltage range 180 – 265 VAC
Charge current, normal mode 30A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 3
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
BlueSmart IP22 Charger 12/30(1) 230V CEE 7/7
R3,475.98
Input voltage range 180 – 265 VAC
Charge current, normal mode 30A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 1
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
BlueSmart IP22 Charger 12/20(3) 230V CEE 7/7
R3,293.75
Input voltage range 180 – 265 VAC
Charge current, normal mode 20A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 3
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
BlueSmart IP22 Charger 12/20(1) 230V CEE 7/7
R2,908.93
Input voltage range 180 – 265 VAC
Charge current, normal mode 20A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 1
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
BlueSmart IP22 Charger 12/15(3) 230V CEE 7/7
R2,780.96
Input voltage range 180 – 265 VAC
Charge current, normal mode 15A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 3
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
BlueSmart IP22 Charger 12/15(1) 230V CEE 7/7
R2,433.98
Input voltage range 180 – 265 VAC
Charge current, normal mode 15A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 1
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
Geyserwise 200L PV Waterheating System Installed With COC
The system makes use of photovoltaic technology and a unique PTC AC/DC element to heat the water
in the geyser. This differs from the traditional thermal hot water systems where water is cycled from a
collector through pipes to the hot water cylinder by either making use of a 220V pump, 12V pump or
thermo siphoning.
Advantages over thermal hot water systems are as follows:
Any existing geyser can be converted
No Additional plumbing is required
No pumps necessary to circulate water
No risk of damaged panels in frost prone areas
The water temperature can be controlled on very hot summer days – reduced risk of overheating
problems
Suitable in all water conditions
Suitable in areas where the geyser is not situated near the panels
Modular system – can be expanded to build off-grid power system for the homeGeyserwise 150L PV Waterheating System Installed With COC
The system makes use of photovoltaic technology and a unique PTC AC/DC element to heat the water
in the geyser. This differs from the traditional thermal hot water systems where water is cycled from a
collector through pipes to the hot water cylinder by either making use of a 220V pump, 12V pump or
thermo siphoning.
Advantages over thermal hot water systems are as follows:
Any existing geyser can be converted
No Additional plumbing is required
No pumps necessary to circulate water
No risk of damaged panels in frost prone areas
The water temperature can be controlled on very hot summer days – reduced risk of overheating
problems
Suitable in all water conditions
Suitable in areas where the geyser is not situated near the panels
Modular system – can be expanded to build off-grid power system for the homeGeyserwise 100L PV Waterheating System Installed With COC
The system makes use of photovoltaic technology and a unique PTC AC/DC element to heat the water
in the geyser. This differs from the traditional thermal hot water systems where water is cycled from a
collector through pipes to the hot water cylinder by either making use of a 220V pump, 12V pump or
thermo siphoning.
Advantages over thermal hot water systems are as follows:
Any existing geyser can be converted
No Additional plumbing is required
No pumps necessary to circulate water
No risk of damaged panels in frost prone areas
The water temperature can be controlled on very hot summer days – reduced risk of overheating
problems
Suitable in all water conditions
Suitable in areas where the geyser is not situated near the panels
Modular system – can be expanded to build off-grid power system for the home
Shop Grid – 3 ColumnsMarketing2021-03-01T16:11:38+02:00