Blue Smart IP67 Charger 24/12
R3,532.11
Input voltage range and frequency 180-265 VAC 45-65 Hz
Efficiency 96%
No load power consumption 0.5W
Charge voltage ‘absorption’ Normal: 28,8V
High: 29,4V
Li-ion: 28,4V
Charge voltage ‘float’ Normal: 27,6V
High: 27,6V
Li-ion: 27,0V
Charge voltage ‘storage’ Normal: 26,4V
High: 26,4V
Li-ion: 27,0V
Charge current, normal mode 12A
Charge current, LOW 4A
Charge algorithm 5-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +60°C (full rated output up to 40°C) Derate 3% per °C above 40°C
Humidity Up to 100%
Start interrupt option (Si) Short circuit proof, current limit 0,5 A
(12/25 and 24/12 models only) Output voltage: max one volt lower than main output
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with CEE 7/7 plug
Protection category IP67
Weight (kg) 2,4
Dimensions (h x w x d in mm) 99 x 219 x 65
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-6-3, EN 61000-3-2
Automotive Directive EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Quattro 48/5000/70-100/100
R29,057.86
32% Off
Two AC inputs with integrated transfer switch
The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
the battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel operation
Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
power and 840 Amps charging capacity.
Split phase options
Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30kW / 36kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
Three phase capability
Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
being overloaded.
PowerAssist – Boosting shore or generator power
This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
be changed remotelyQuattro 24/5000/120-100/100
R40,604.43
23% Off
Two AC inputs with integrated transfer switch
The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
the battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel operation
Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
power and 840 Amps charging capacity.
Split phase options
Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30kW / 36kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
Three phase capability
Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
being overloaded.
PowerAssist – Boosting shore or generator power
This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
be changed remotely30W Atlas Surge Protected LED Flood Light AC220V 2700 Lumens
R171.93
Features and Benefits
Discreet but powerful and long lasting, this floodlight is perfectly suited for commercial and repetitive usage,
but will also be at home in your residence or garden.
The younger brother of the Elite, this floodlight is by no means little, with a massive 1KV or 2KV surge
protection in a compact driver-on-board housing.
The design allows for auto-production which provides a truly stable, reliable and cost effective solution to
the floodlight market.
Using the newest technology, the Mesmerize Atlas range implements excellent weatherproofing and
ventilation functions called ePTEF technology.
As with most of the Mesmerize Floodlights, the Atlas comes with a 1meter H05-graded cable and an
oblique angled bracket for even easier and faster installations.
It is rated up to 25 000 hours of life and has up to 100 lumens per watt, this product carries a 2 Year Warranty.Geyserwise 200L PV Waterheating System Installed With COC
The system makes use of photovoltaic technology and a unique PTC AC/DC element to heat the water
in the geyser. This differs from the traditional thermal hot water systems where water is cycled from a
collector through pipes to the hot water cylinder by either making use of a 220V pump, 12V pump or
thermo siphoning.
Advantages over thermal hot water systems are as follows:
Any existing geyser can be converted
No Additional plumbing is required
No pumps necessary to circulate water
No risk of damaged panels in frost prone areas
The water temperature can be controlled on very hot summer days – reduced risk of overheating
problems
Suitable in all water conditions
Suitable in areas where the geyser is not situated near the panels
Modular system – can be expanded to build off-grid power system for the home
Shop Grid – 3 ColumnsMarketing2021-03-01T16:11:38+02:00