50W Hydra LED Solar Floodlight
R669.99
Hydra 50W is a LED Solar Floodlight that is serving innovation and continues to operate up to 12 hours, so you can say goodbye to Eskom!Trust the sun! to convert energy into power, so if you like having options, you now have them.- Easy to install anywhere there is sunshine, the NEW Mesmerize Hydra Solar Floodlight will provide you with up to 12 hours of light without relying on power from the grid!
- The 50w have an siren function that flashes red and blue to deter any would-be criminals
- Built-in with LEDs
- 3 meter cable available
- 6-8 hours charging time
- Equipped with IK06 and IP67
Multiplus 24/3000/70-50
R20,987.50
27% Off
Multiplus, Multifunctional, with intelligent power management
The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shoreside or grid power
The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.
BlueSmart IP22 Charger 12/15(3) 230V CEE 7/7
R2,780.96
Input voltage range 180 – 265 VAC
Charge current, normal mode 15A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 3
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
Victron Energy BlueSolar MPPT Charge Controller 100/50
R3,062.34
44% Off
BlueSolar MPPT 100/50 (12/24V – 50A)
Charge current up to 50 A and PV voltage up to 75 V, respectively 100 V
The BlueSolar Charge Controller will charge a lower nominal voltage battery with a higher nominal voltage PV array. The controllers automatically adjust to 12 V or 24 V nominal battery voltage.Feature Highlights
- Ultra-fast Maximum Power Point Tracking (MPPT)
- Advanced Maximum Power Point Detection in case of partial shading conditions
- Load output on the small models
- BatteryLife: intelligent battery management by load shedding
- Automatic battery voltage recognition
- Flexible charge algorithm
- Over-temperature protection and power de-rating when temperature is high
All Victron Energy MPPT Charge Controllers are compatible with the Color Control GX: The Color Control GX provides intuitive control and monitoring for all products connected to it. The list of Victron products that can be connected is endless: Inverters, Multis, Quattros, MPPT 150/70, BMV-600 series, BMV-700 series, Skylla-i, Lynx Ion and even more.
Blue Smart IP67 Charger 12/25
R3,679.31
Input voltage range and frequency 180-265 VAC 45-65 Hz
Efficiency 95%
No load power consumption 0.5W
Charge voltage ‘absorption’ Normal: 14,4V
High: 14,7V
Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V
High: 13,8V
Li-ion: 13,5V
Charge voltage ‘storage’ Normal: 13,2V
High: 13,2V
Li-ion: 13,5V
Charge current, normal mode 25A
Charge current, LOW 10A
Charge algorithm 5-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +60°C (full rated output up to 40°C) Derate 3% per °C above 40°C
Humidity Up to 100%
Start interrupt option (Si) Short circuit proof, current limit 0,5 A
(12/25 and 24/12 models only) Output voltage: max one volt lower than main output
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with CEE 7/7 plug
Protection category IP67
Weight (kg) 2,4
Dimensions (h x w x d in mm) 99 x 219 x 65
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-6-3, EN 61000-3-2
Automotive Directive EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Shop Grid – 3 ColumnsMarketing2021-03-01T16:11:38+02:00











