Victron – BlueSolar PWM-Light 10A 12/24V Charge Controller
R548.63
The BlueSolar Charger series uses Pulse Width Modulation (PWM) charge voltage control combined with a multistage charge control algorithm. This leads to superior charging and enhanced battery performance. The filtered PWM power control system uses highly efficient and reliable power MOSFET transistors.
Fully automatic temperature compensation of charge voltage is available to improve charge control and battery performance.
Features
· Internal temperature sensor.
· Three-stage battery charging [bulk – absorption – float], not programmable
· Protected against overcurrent.
· Load output protected against overload and short circuit.
· Protected against reverse polarity connection of the solar panels and/or battery.
· Load output with low battery voltage disconnect function.
· Intelligent software control.
· PWM charging mode.
· Two digit seven segment display for the quick and easy setting of the load output functionality, incl. timer setting.
· Day/night timing options – See manual for details
BlueSolar PWM-Light Charge Controller 12/24V-5A
R410.09
BlueSolar PWM-Light 12/24V-5A
Victron Bluesolar light PWM solar controller:
Victron’s range of PWM and MPPT charge controllers are both widely used to charge batteries with solar power.The PWM controller is in essence a switch that connects a solar array to the battery. The result is that the voltage of the array will be pulled down to near that of the battery.
A PWM controller is not a DC to DC transformer. The PWM controller is a switch which connects the solar panel to the battery. When the switch is closed, the panel and the battery will be at nearly the same voltage. Assuming a discharged battery the initial charge voltage will be around 13 V, and assuming a voltage loss of 0,5 V over the cabling plus controller, the panel will be at Vpwm = 13,5 V.
The voltage will slowly increase with increasing state of charge of the battery. When absorption voltage is reached the PWM controller will start to disconnect and reconnect the panel to prevent overcharge (hence the name: Pulse Width Modulated controller).
Features:
– Load output with low battery voltage disconnect function.
– Lighting control function, one timer only.
– Two digit seven segment display for quick and easy setting of the load output functionality, including timer setting.
– Three stage battery charging (bulk, absorption, float), not programmable.
– Load output protected against over load and short circuit.
– Protected against reverse polarity connection of the solar array and/or battery.
Day/night timing options:
Multiplus 24/500/10-16
R7,501.58
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectVICTRON BLUESOLAR MPPT 75/10 10 AMP SOLAR CHARGE CONTROLLER REGULATOR
R956.19
35% Off
Victron Blue Solar MPPT 75/10 10 Amp (12V/24V) Solar Charge Controller Regulator is the perfect choice for the heavy load projects. The Victron Blue Solar MPPT 75/10 10 Amp (12V/24V) Solar Charge Controller Regulator has a variety of features that ensures you get the best performance from your Solar Panels through to your batteries.
Color Control GX
All Victron Energy MPPT Charge Controllers are compatible with the Color Control GX: The Color Control GX provides intuitive control and monitoring for all products connected to it. The list of Victron products that can be connected is endless: Inverters, Multis, Quattros, MPPT 150/70, BMV-600 series, BMV-700 series, Skylla-i, Lynx Ion and even more.
VRM Online Portal
Besides monitoring and controlling products on the Color Control GX, the information is also forwarded to our free remote monitoring website: the VRM Online Portal. The portal is free of charge.
Related product:EasySolar Minimal wiring and an all-in-one solution: the EasySolar takes power solutions one stage further, by combining an Ultra BlueSolar charge controller (MPPT), an inverter/charger and AC distribution in one enclosure.
Victron Blue Solar MPPT 75/10 10 Amp (12V/24V) Amp Solar Charge Controller Regulator
Ultra-fast Maximum Power Point Tracking (MPPT)Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.
Load outputOver-discharge of the battery can be prevented by connecting all loads to the load output. The load output will disconnect the load when the battery has been discharged to a pre-set voltage. Alternatively, an intelligent battery management algorithm can be chosen: see Battery Life. The load output is short circuit proof. Some loads (especially inverters) can best be connected directly to the battery, and the inverter remote control connected to the load output. A special interface cable may be needed, please see the manual
Battery Life: intelligent battery managementWhen a solar charge controller is not able to recharge the battery to its full capacity within one day, the result is often that the battery will continually be cycled between a ‘partially charged’ state and the ‘end of discharge’ state. This mode of operation (no regular full recharge) will destroy a lead-acid battery within weeks or months. The Battery Life algorithm will monitor the state of charge of the battery and, if needed, day by day slightly increase the load disconnect level (i.e. disconnect the load earlier) until the harvested solar energy is sufficient to recharge the battery to nearly the full 100%. From that point onwards the load disconnect level will be modulated so that a nearly 100% recharge is achieved about once every week.
Programmable battery charge algorithmSee the software section on our website for details
Day/night timing and light dimming optionSee the software section on our website for details
Programming, real-time data and history display options– Modern Apple and Android smartphones, tablets, macbooks and other devices: see the VE.Direct Bluetooth Smart dongle an and the MPPT app discovery sheet for screenshots.
– ColorControl panel
**Note: Phone or Tablet Programming, real-time data and history display options as seen in photos require VE.Direct Bluetooth Dongle available in our Store as Optional Extra
Blue Smart IP67 Charger 12/25
R3,679.31
Input voltage range and frequency 180-265 VAC 45-65 Hz
Efficiency 95%
No load power consumption 0.5W
Charge voltage ‘absorption’ Normal: 14,4V
High: 14,7V
Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V
High: 13,8V
Li-ion: 13,5V
Charge voltage ‘storage’ Normal: 13,2V
High: 13,2V
Li-ion: 13,5V
Charge current, normal mode 25A
Charge current, LOW 10A
Charge algorithm 5-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +60°C (full rated output up to 40°C) Derate 3% per °C above 40°C
Humidity Up to 100%
Start interrupt option (Si) Short circuit proof, current limit 0,5 A
(12/25 and 24/12 models only) Output voltage: max one volt lower than main output
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with CEE 7/7 plug
Protection category IP67
Weight (kg) 2,4
Dimensions (h x w x d in mm) 99 x 219 x 65
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-6-3, EN 61000-3-2
Automotive Directive EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Shop Grid – 3 ColumnsMarketing2021-03-01T16:11:38+02:00











