Shop Grid – 3 Columns2021-03-01T16:11:38+02:00
  • Cinco 160W 36 Cell Poly Solar Panel Off-Grid

    • Rating: 160W
    • Efficiency: 15.9%
    • Width: 680mm
    • Height: 1,480mm
    • Price per Watt: (R6,383/Wp)

    36 Cell  Polycrystalline Solar Panel

    • Rigirous quality control meeting highest international standards
    • High-transmissivity low-iron tempered glass, stong aluminium frame using UV-resistant silicon.
    • Aesthetic appearance with excellent efficiency based on innovative photovoltaic technologies.
    • 10 years limited product warranty
    • 10 years @ 90% of the minimal rated power output
    • 25 years @ 80% of the minimal rated power output

     

    View product
  • 8KW DEYE HYBRID INVERTER 1 PHASE, 48V, 2 MPPT

    R23,805.00

    37% Off

    View product
  • Multiplus 24/3000/70-16

    R19,186.37

    28% Off

    Multiplus, Multifunctional, with intelligent power management

    The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.

    Two AC Outputs

    The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).

    Virtually unlimited power thanks to parallel operation

    Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.

    Three phase capability

    In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.

    Split phase options

    Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.

    PowerControl – Dealing with limited generator, shoreside or grid power

    The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

    PowerAssist – Boosting the capacity of shore or generator power

    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

    Four stage adaptive charger and dual bank battery charging

    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.

    System configuring has never been easier

    After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.

    View product
  • Quattro 12/3000/120-50/50

    R30,115.97

    26% Off

    Two AC inputs with integrated transfer switch
    The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
    generators. The Quattro will automatically connect to the active source.
    Two AC Outputs
    The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
    grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
    the battery, like a water heater for example, can be connected to this output.
    Virtually unlimited power thanks to parallel operation
    Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
    power and 840 Amps charging capacity.
    Split phase options
    Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
    phase, to supply up to 30kW / 36kVA of split phase power.
    Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
    www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
    Three phase capability
    Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
    connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
    supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
    account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
    being overloaded.
    PowerAssist – Boosting shore or generator power
    This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
    capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
    make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
    the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
    a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
    Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
    tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
    be changed remotely

    View product
  • MultiPlus-II 48/5000/70-50

    R15,434.15

    53% Off

    A MultiPlus, plus ESS (Energy Storage System) functionality
    The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
    currentsensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
    The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
    It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
    Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
    PowerControl and PowerAssist – Boosting the capacity of the grid or a generator
    A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
    whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
    function).
    PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
    limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
    When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
    compatible with both solar charger controllers and grid-tie inverters.
    Two AC Outputs
    The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
    a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
    battery, like a water heater for example, can be connected to this output.
    Virtually unlimited power thanks to parallel and three phase operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
    25 kW / 30 kVA output power with 420 Amps charging capacity.
    In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
    all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
    capacity.
    On-site system configuring, monitoring and control
    Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
    needed).
    Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer,
    Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
    Remote configuring and monitoring
    Install a Color Control GX or other GX product to connect to the internet.
    Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    When connected to the internet, systems can be accessed remotely, and settings can be changed.

    View product
  • Cover for Dewhot gas geyser (medium)

    View product
  • Suntree DC Surge Protection 40kA 2P 600V

    R463.50

    View product
  • 12V Water Pump with Pressure Switch, 3.8L/min, 2.4 Bar – Self-Priming

    R999.99

    View product
  • 16L Constant Temperature Gas Geyser (16CT)- Type D

    Multiple use application geyser (run multiple outlets simultaneously)

    This smart geyser automatically adjusts itself to the water flow. With multiple outlets running simultaneously your water temperature will always remain hot and constant regardless of the water demand.

    TYPE D
    For outdoor use under a cover

    Features

    • Touch button temperature control
    • 84% energy efficiency
    • Gas efficient – reduces gas consumption according to flow demand
    • Anti-freeze function
    • Start up/ geyser function can also operate on low water pressure
    • Requires no electricity – flame ignition and geyser function are battery operated
    • Compatible with mixer taps
    • Flame failure safety device
    View product
  • Multiplus 24/500/10-16

    R7,501.58

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • CABLE PERMOPOWER 35MM RED

    R112.70

    View product
  • DC12V 70W 130PSI 6L/Min High Pressure Diaphragm Self Priming Water Pump Automatic Switch

    R807.01

    Specifications :
    Volts : 12V/24VDC,220VAC
    Amps : 6A
    Rateapower:70W
    Pressure : 0.90MPA(MAX 130PSI)
    Thelargestflow: 6L/MIN
    Working medium: no oil, no strong corrosive, non-acid and alkali, without solid particles of liquid;
    Medium temperature: 0 -100
    Inlet and outlet size: 10mm
    Size: 16.5 × 10 × 6.2cm
    Type: Size 1 :Straight ,
    Size 2: Screw Thread
    Weight : 598g straight
    582g Screw thread

    View product

Title

Go to Top