Multiplus 12/3000/120-50
R23,007.13
20% Off
Multiplus, Multifunctional, with intelligent power management
The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shoreside or grid power
The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.
Victron Energy SmartSolar MPPT 100 | 30
R2,288.27
46% Off
The smart solar 100/30 is designed to accept solar panel (PV) input up to 440W at 12V or 880W at 24V and has a rated charge current of 30A.
However, you should note both the open circuit voltage (Voc) and the short circuit current (Isc) of your combined solar panels and ensure this does not exceed the maximum input of the MPPT charge controller. For the 100/30 the maximum PV open circuit voltage (Voc) is 100V and the maximum PV short circuit current (Isc) is 35A.
Auto-selects 12/24V on the output. The charge controller once connected will automatically recognise your battery bank voltage.220W
Bluetooth Monitoring built-in. Remotely control and monitor the extensive features of your SmartSolar MPPT charge controller with built-in bluetooth by pairing it with your smartphone or tablet via the VictronConnect app. (Bluetooth dongle not required)
BlueSmart IP22 Charger 12/30(3) 230V CEE 7/7
R3,951.92
Input voltage range 180 – 265 VAC
Charge current, normal mode 30A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 3
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
Revov LiFe 51.2 V – 11.2kWh 220Ah
LiFePO4 chemistry is very safe even if fully
charged.
• Reliability – battery designed to operate in
almost any environment.
• Supports parallel bus bar connection.
• External BMS.
• Manufacturing plants comply with the
legislation in each country and with
international quality standards ISO9001 and
Qs9000.
• Residential, Business, Factory, Data Centres or
Telecoms Base Station backup.
• Solar, Wind or Hybrid Storage.
• Reduced Peak Usage Charges from the Grid.The REVOV LiFePO4 51.2V C8 is an energy
storage Lithium Iron Phosphate battery
designed to be part of an inverter-controlled
energy storage system for residential,
business or factory power backup.
REVOV’S superior 16 cell confi guration is
made up of automotive grade cells, which
is designed to withstand harsher conditions,
extreme temperatures and with a
higher energy density.
The C8 battery utilises cells manufactured
by the largest producer of LiFePO4 cells
supporting renewable storage projects
across Europe, UK, Japan and has been a
long time supplier to companies like BMW,
Volkswagen andBlue Smart IP67 Charger 24/12
R3,532.11
Input voltage range and frequency 180-265 VAC 45-65 Hz
Efficiency 96%
No load power consumption 0.5W
Charge voltage ‘absorption’ Normal: 28,8V
High: 29,4V
Li-ion: 28,4V
Charge voltage ‘float’ Normal: 27,6V
High: 27,6V
Li-ion: 27,0V
Charge voltage ‘storage’ Normal: 26,4V
High: 26,4V
Li-ion: 27,0V
Charge current, normal mode 12A
Charge current, LOW 4A
Charge algorithm 5-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +60°C (full rated output up to 40°C) Derate 3% per °C above 40°C
Humidity Up to 100%
Start interrupt option (Si) Short circuit proof, current limit 0,5 A
(12/25 and 24/12 models only) Output voltage: max one volt lower than main output
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with CEE 7/7 plug
Protection category IP67
Weight (kg) 2,4
Dimensions (h x w x d in mm) 99 x 219 x 65
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-6-3, EN 61000-3-2
Automotive Directive EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Blue Smart IP67 Charger12/7
R1,760.65
8% Off
Input voltage range and frequency 180-265 VAC 45-65 Hz
Efficiency 93%
No load power consumption 0.5W
Charge voltage ‘absorption’ Normal: 14,4V
High: 14,7V
Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V
High: 13,8V
Li-ion: 13,5V
Charge voltage ‘storage’ Normal: 13,2V
High: 13,2V
Li-ion: 13,5V
Charge current, normal mode 7A
Charge current, LOW 2A
Charge algorithm 5-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +60°C (full rated output up to 40°C) Derate 3% per °C above 40°C
Humidity Up to 100%
Start interrupt option (Si) Short circuit proof, current limit 0,5 A
(12/25 and 24/12 models only) Output voltage: max one volt lower than main output
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with CEE 7/7 plug
Protection category IP67
Weight (kg) 1,8
Dimensions (h x w x d in mm) 85 x 211 x 60
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-6-3, EN 61000-3-2
Automotive Directive EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Quattro 12/5000/220-100/100
R46,440.57
26% Off
Two AC inputs with integrated transfer switch
The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
the battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel operation
Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
power and 840 Amps charging capacity.
Split phase options
Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30kW / 36kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
Three phase capability
Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
being overloaded.
PowerAssist – Boosting shore or generator power
This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
be changed remotelyRCT Axpert MAX 8kVA 8kW 48V Hybrid Inverter
R21,503.74
Features
- Customizable status LED bar with RGB breathing lights.
- Built-in Wi-Fi for mobile monitoring (Android/iOS App is available).
- Supports USB On-the-Go function.
- Reserved communication port for BMS (RS485, CAN-BUS or RS232).
- Replaceable fan design for ease of maintenance.
- Battery independency design enhances this inverter to operate without a battery connected provided there is a grid connection.
- Enhanced AC/Solar charger to 120A.
- Built-in anti-dust kit.
- Parallel operation up to 6 units.
Blue Smart IP67 Charger 12/17
R2,491.62
Input voltage range and frequency 180-265 VAC 45-65 Hz
Efficiency 95%
No load power consumption 0.5W
Charge voltage ‘absorption’ Normal: 14,4V
High: 14,7V
Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V
High: 13,8V
Li-ion: 13,5V
Charge voltage ‘storage’ Normal: 13,2V
High: 13,2V
Li-ion: 13,5V
Charge current, normal mode 17A
Charge current, LOW 6A
Charge algorithm 5-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +60°C (full rated output up to 40°C) Derate 3% per °C above 40°C
Humidity Up to 100%
Start interrupt option (Si) Short circuit proof, current limit 0,5 A
(12/25 and 24/12 models only) Output voltage: max one volt lower than main output
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with CEE 7/7 plug
Protection category IP67
Weight (kg) 2,4
Dimensions (h x w x d in mm) 99 x 219 x 65
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-6-3, EN 61000-3-2
Automotive Directive EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Victron BlueSolar PWM-Light Charge Controller 48V-30A
R1,159.43
Victron BlueSolar PWM-Light Charge Controller 48V-30A, 2 Year Warranty.
BlueSolar PWM-Light
- Load output with low battery voltage disconnect function.
- Lighting control function, one timer only.
- Two digit seven segment display for quick and easy setting of the load output functionality, including timer setting.
- Three stage battery charging (bulk, absorption, float), not programmable.
- Load output protected against over load and short circuit.
- Protected against reverse polarity connection of the solar array and/or battery.
- Day/night timing options: see manual for details
Features:
- Load output with low battery voltage disconnect function.
- Lighting control function, one timer only.
- Seven segment display for quick and easy setting of the load output functionality, including timer setting.
- Three stage battery charging (bulk, absorption, float), not programmable.
- Load output protected against over load and short circuit.
- Protected against reverse polarity connection of the solar array and/or battery
70L 3Way Camping Freezer(Gas,220V,12V)
R6,500.00
25% Off
Interesting Facts
A dual battery system is not required as the 12v function is only used while
travelling.
Gas or 220V is used when stationary so there is no need for forced drives to charge batteries.Your freezer
: has 75mm foam insulation which increases your cold hold over time when not switched
on compared to other freezers.
: has no moving parts inside the absorption system which makes repair and maintenance
inexpensive.
: is level sensitive hence proper levelling must be done when stationary.
: is proudly manufactured in South Africa.
: is capable of freezing to 44°C below ambient.
Example: -12°C @ 32°C
-20°C @ 20°C
: is capable of freezing 2 kg of water in 24 hours while keeping everything else frozen.
: is equipped with a gas safety valve which will cut the gas flow to the
burner in less than 60 seconds in the event of the burner flame going out.
: will only use between 400 – 500g of gas per 24 hours. A 9 kg gas bottle will last you
approximately 18 – 21 days.
: gas function is ideal for those unforeseen black outs at home.
Your Cooler Box
: has 75mm foam for maximum insulation.
: has a aluminium bin to transfer the cold all around.
: is perfect to keep you meat frozen for those long weekends.
Shop Grid – 3 ColumnsMarketing2021-03-01T16:11:38+02:00























