Sunsynk Battery 100AH 5.32KWH 51.2V (SUNBATT-5.32)
R19,320.00
33% Off
L051100-A Energy Storage System is consisted of 2 sets of M025100-A modules manufactured by
Sunsynk. In each M025100-A, there are 8 pcs of 100 Ah LFP cell originated from CATL. The overall
system also provides standard communication port, i.e. CAN and RS485, to monitor the working status
and communicate with upper machine as well as the Power Conversion System (PCS) in front.
Multiplus COMPACT 24/2000/50-30
R16,168.43
25% Off
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
settings can be changed remotely.Victron Energy BlueSolar MPPT Charge Controller 100/50
R3,062.34
44% Off
BlueSolar MPPT 100/50 (12/24V – 50A)
Charge current up to 50 A and PV voltage up to 75 V, respectively 100 V
The BlueSolar Charge Controller will charge a lower nominal voltage battery with a higher nominal voltage PV array. The controllers automatically adjust to 12 V or 24 V nominal battery voltage.Feature Highlights
- Ultra-fast Maximum Power Point Tracking (MPPT)
- Advanced Maximum Power Point Detection in case of partial shading conditions
- Load output on the small models
- BatteryLife: intelligent battery management by load shedding
- Automatic battery voltage recognition
- Flexible charge algorithm
- Over-temperature protection and power de-rating when temperature is high
All Victron Energy MPPT Charge Controllers are compatible with the Color Control GX: The Color Control GX provides intuitive control and monitoring for all products connected to it. The list of Victron products that can be connected is endless: Inverters, Multis, Quattros, MPPT 150/70, BMV-600 series, BMV-700 series, Skylla-i, Lynx Ion and even more.
Multi-function Triangle Signal Warning Light Portable COB LED Work Light Flood Lamp SOS Camping Searchlight LED Traffic Lighting
R253.00
Feature:
Plastic shell wrapped in a layer of carbon black, feel good, non-slip.
Come with magnet and hook, Folding design, easy to use in a small space inside.
High COB LED,Low COB LED ,red led ,red sos led ,4-different lighting modes to meet your lighting needs.
LED bulbs, green energy saving and environmental protection, the use of longer time.
AA OR 18650 battery, you can use the USB cable to charge.Product parameters:
4-mode: high/ low/ red/red sos
Size: 210 x 210 mm
Weight: 500g
Power supply: 4pcs aa or 2 pcs 18650 batteryPackage Included:
1 x LED light2 pcs 18650 battery
Color Control GX
R3,326.84
39% Off
The Color Control GX is the communication-centre of your installation. It offers at-a-glance live information, and lets you control all products connected to it. Full system control is gained – almost anywhere in the world – by accessing your Color Control GX using our free-to-use Victron Remote Management Portal (VRM).
50W Hydra LED Solar Floodlight
R669.99
Hydra 50W is a LED Solar Floodlight that is serving innovation and continues to operate up to 12 hours, so you can say goodbye to Eskom!Trust the sun! to convert energy into power, so if you like having options, you now have them.- Easy to install anywhere there is sunshine, the NEW Mesmerize Hydra Solar Floodlight will provide you with up to 12 hours of light without relying on power from the grid!
- The 50w have an siren function that flashes red and blue to deter any would-be criminals
- Built-in with LEDs
- 3 meter cable available
- 6-8 hours charging time
- Equipped with IK06 and IP67
Multiplus 48/500/6-16
R7,195.27
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connect
Shop Grid – 3 ColumnsMarketing2021-03-01T16:11:38+02:00











