DC12V 70W 130PSI 6L/Min High Pressure Diaphragm Self Priming Water Pump Automatic Switch
R807.01
Specifications :
Volts : 12V/24VDC,220VAC
Amps : 6A
Rateapower:70W
Pressure : 0.90MPA(MAX 130PSI)
Thelargestflow: 6L/MIN
Working medium: no oil, no strong corrosive, non-acid and alkali, without solid particles of liquid;
Medium temperature: 0 -100
Inlet and outlet size: 10mm
Size: 16.5 × 10 × 6.2cm
Type: Size 1 :Straight ,
Size 2: Screw Thread
Weight : 598g straight
582g Screw threadBLUESOLAR PWM-LIGHT 12/24V-20A
R731.85
Victron Bluesolar light PWM solar controller:
Victron’s range of PWM and MPPT charge controllers are both widely used to charge batteries with solar power.The PWM controller is in essence a switch that connects a solar array to the battery. The result is that the voltage of the array will be pulled down to near that of the battery.
A PWM controller is not a DC to DC transformer. The PWM controller is a switch which connects the solar panel to the battery. When the switch is closed, the panel and the battery will be at nearly the same voltage. Assuming a discharged battery the initial charge voltage will be around 13 V, and assuming a voltage loss of 0,5 V over the cabling plus controller, the panel will be at Vpwm = 13,5 V.
The voltage will slowly increase with increasing state of charge of the battery. When absorption voltage is reached the PWM controller will start to disconnect and reconnect the panel to prevent overcharge (hence the name: Pulse Width Modulated controller).
Features:
– Load output with low battery voltage disconnect function.
– Lighting control function, one timer only.
– Two digit seven segment display for quick and easy setting of the load output functionality, including timer setting.
– Three stage battery charging (bulk, absorption, float), not programmable.
– Load output protected against over load and short circuit.
– Protected against reverse polarity connection of the solar array and/or battery.
BlueSmart IP22 Charger 12/30(3) 230V CEE 7/7
R3,951.92
Input voltage range 180 – 265 VAC
Charge current, normal mode 30A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 3
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
Multiplus 24/1200/25-16
R12,990.84
PowerControl / PowerAssist Yes
Three Phase and parallel operation Yes
Transfer switch 16A
INVERTER
Input voltage range 9,5 – 17V 19 – 33V 38– 66V
Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
Cont. output power at 25°C (3) 1200VA
Cont. output power at 25°C 1000W
Cont. output power at 40°C 900W
Cont. output power at 65°C 600W
Peak power 2400W
Maximum efficiency 93 / 94 / 95%
Zero-load power 10 / 9 / 10W
Zero-load power in search mode 3/ 3 / 3W
CHARGER
AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
Charge voltage ‘absorption’ 14,4 / 28,8 / 57,6V
Charge voltage ‘float’ 13,8 / 27,6 / 55,2V
Storage mode 13,2 / 26,4 /52,8V
Charge current house battery (4) 50 / 25 / 13A
Charge current starter battery 1A (12V and 24V models only)
Battery temperature sensor Yes
GENERAL
Programmable relay (5) Yes
Protection (2) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
(RJ45-spliter ASS030065510 needed for 500/800/12ooVA models)
Remote on-off On/off/charger only On/off
DIP switches Yes (6) Yes (3)
Internal DC fuse 200/100/50A
Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
Battery-connection 35 / 25 / 10 mm²
230V AC-connection G-ST18i connector
Weight 8,2 kg
Dimensions (h x w x d) 406 x 250 x 100 mm
STANDARDS
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles ECE R10-5
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for:
general alarm, DC under voltage or generator start/stop signal function
AC rating: 230V/4A
DC rating: 4A up to 35VDC, 1A up to 60VDCCinco 120W 36 Cell Poly Solar Panel Off-Grid
- Rating: 120W
- Efficiency: 15%
- Width: 680mm
- Height: 1,180mm
- Price per Watt: (R7,424/Wp)
36 Cell Polycrystalline Solar Panel
- Rigirous quality control meeting highest international standards
- High-transmissivity low-iron tempered glass, stong aluminium frame using UV-resistant silicon.
- Aesthetic appearance with excellent efficiency based on innovative photovoltaic technologies.
- 10 years limited product warranty
- 10 years @ 90% of the minimal rated power output
- 25 years @ 80% of the minimal rated power output
Shop Grid- 4 ColumnsMarketing2021-03-01T16:55:57+02:00











