Cinco 160W 36 Cell Poly Solar Panel Off-Grid
- Rating: 160W
- Efficiency: 15.9%
- Width: 680mm
- Height: 1,480mm
- Price per Watt: (R6,383/Wp)
36 Cell Polycrystalline Solar Panel
- Rigirous quality control meeting highest international standards
- High-transmissivity low-iron tempered glass, stong aluminium frame using UV-resistant silicon.
- Aesthetic appearance with excellent efficiency based on innovative photovoltaic technologies.
- 10 years limited product warranty
- 10 years @ 90% of the minimal rated power output
- 25 years @ 80% of the minimal rated power output
20L Room Sealed Fan Forced Gas Geyser (RS20)
Shipped with a Free Flexi Flue
Multiple use application geyser (run multiple outlets simultaneously)
The cutting edge RS20 is equipped with many unique features and is constructed out of high quality components. Versatile and compact, the RS20 is one of the safest and most efficient gas water heaters on the market.
TYPE C
For outdoor use under a cover with shortened flue or indoor use with a flueFeatures
- Heavy duty copper radiator
- 88% energy efficiency
- Can be installed in confined and unventilated spaces
- Wind resistent burner
- Anti-freeze function
- Touch button temperature control
- Compatible with mixer taps
- Ensures constant temperature when multiple outlets are used simultaneously
- Compact design with a brushed aluminum cover
- Flame failure safety device
- Inverter compatible
Multiplus 48/3000/35-16
R13,848.07
36% Off
Multifunctional, with intelligent power management
The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge
technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the
MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of
a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output (second output available on models rated at
3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide
15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three
strings of six parallel units a 45 kW / 54 kVA three phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30 kW / 36 kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore
current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus
preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will
make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software.
The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage
for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger
datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second
battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go.
If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even
parallel and 3-phase operation can be programmed with DIP switches: no computer needed!
Alternatively, VE.Net can be used instead of the DIP switches.
And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several
new, advanced, featuresBlue Smart IP22 Charger 24V, 1 output 12A
R2,982.58
Input voltage range 180 – 265 VAC
Charge current, normal mode 12A
Charge current, NIGHT or LOW 4 / 6 / 8 A
Efficiency 94%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 1
Charge voltage ‘absorption’ Normal: 28,8V High: 29,4V Li-ion: 28,4V
Charge voltage ‘float’ Normal: 27,6V High: 27,6V Li-ion: 27,0V
Charge voltage ‘storage Normal: 26,4V High: 26,4V Li-ion: 27,0V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
Multiplus 24/800/16-16
R9,014.24
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectGeyserwise 100L PV Waterheating System Installed With COC
The system makes use of photovoltaic technology and a unique PTC AC/DC element to heat the water
in the geyser. This differs from the traditional thermal hot water systems where water is cycled from a
collector through pipes to the hot water cylinder by either making use of a 220V pump, 12V pump or
thermo siphoning.
Advantages over thermal hot water systems are as follows:
Any existing geyser can be converted
No Additional plumbing is required
No pumps necessary to circulate water
No risk of damaged panels in frost prone areas
The water temperature can be controlled on very hot summer days – reduced risk of overheating
problems
Suitable in all water conditions
Suitable in areas where the geyser is not situated near the panels
Modular system – can be expanded to build off-grid power system for the homeMultiplus 48/500/6-16
R7,195.27
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connect16L EcoDew Gas Geyser
The 16l Dewhot Ecodew white powder coated gas water heater is suitable for a bathroom with a bath, shower and wash hand basin.
This unit is suitable for outdoor installation only.TYPE D
For outdoor use under a cover with a flue.Features
- Requires no electricity – flame ignition and geyser function are battery operated
- 84% energy efficiency
- Neat and compact
- Stainless steel cover
- LCD temperature display
- Flame failure safety device
- Anti-freeze function
Urna elit, sem lobortis faucibus facilisi vel lectus etiam phasellus odio.
Shop men
Morbi leo sagittis placerat sem. Nisl tincidunt nulla fames nisl risus egestas.
Morbi leo sagittis placerat sem. Nisl tincidunt nulla fames nisl risus egestas.
Subscribe to our newsletter and get 10% Off!
Velit morbi sed non est dolor tellus fringilla diam