Multiplus COMPACT 24/2000/50-30
R16,168.43
25% Off
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
settings can be changed remotely.Victron BlueSolar MPPT 75/15
R965.08
41% Off
The Victron MPPT 75/15 (MPN SCC010015050R) is part of the BlueSolar MPPT charge controller familiy and provides ultra-fast powertracking which extends your solar system’s output.
Next generation MPP-tracker
Especially on clouded days with changing light intensity a MPPT controler increases your system output by up to 30% compared to PWM charge controllers. Moreover the 75/15 comes with further innovative technologies.Programming, real-time data and logging
Latest Apple and Android devices (smartphones, tablets,…) can be connected via VE.Direct over Bluetooth Smart Dongles and the MPPT App or via the GX Color control.
Please note that the Bluetooth Smart dongle and the GX Color Control are not included in the delivery scope but available separately.Important features:
- Ultra-fast MPP-tracker ensures highest possible outcome even when it is cloudy
- Integrated VE.Direct data port for connecting devices like the Bluetooth Smart Dongle or the GX Color Control panel
- Suitable for 12V and 24V systems
- Rated charging amperage: 15A
- 200W max. PV-performance at 12V and 400W at 24V
- 15A consumer output with auto-shutdown at imminent battery undervoltage (deep discharge protection)
- Reverse polarity protection
- Multistep adaptive charging algorithm
- Battery charging algorithm programmable
- Integrated battery life algorithm extends battery life when activated and all consumers are connected to the consumer output
- Day/night-time control and dimming options
VE.Direct data port integrated
VE.Direct transfers important parameters to all devices connected to the charge controller and allows communication to equipment such as the Bluetooth Smart Dongle or the GX Color Control. The VE.Direct data port is meant for products where a full canbus integration would produce extreme costs. Please check our Victron brand section for more information about VE.Direct.Integrated battery life algorithm extends battery life
If the charge controller can’t manage to fully charge the battery within a day the battery status switches constantly between “partly charged” and “end of discharge”. This operation mode (no regular charging) is ideal for small lead batteries, for lead-acid batteries otherwise irregular charging and discharging can cause severe damage already after several months.
The battery life algorithm checks the battery’s charging level and heightens the switch-off threshold from day to day. That means that connected consumers are switched off earlier until the produced energy is sufficient for a full battery charge of 100%. From this point on the threshold is modulated in a way that a full charge can be reached once a week.Delivery Scope:
1x Victron SCC010015050R BlueSolar MPPT 75/15 12V 24V 15A charge controller
1x ManualDC12V 70W 130PSI 6L/Min High Pressure Diaphragm Self Priming Water Pump Automatic Switch
R807.01
Specifications :
Volts : 12V/24VDC,220VAC
Amps : 6A
Rateapower:70W
Pressure : 0.90MPA(MAX 130PSI)
Thelargestflow: 6L/MIN
Working medium: no oil, no strong corrosive, non-acid and alkali, without solid particles of liquid;
Medium temperature: 0 -100
Inlet and outlet size: 10mm
Size: 16.5 × 10 × 6.2cm
Type: Size 1 :Straight ,
Size 2: Screw Thread
Weight : 598g straight
582g Screw threadHubble AM2 5.5KWH 51V Wall Mounted Cell Lithium-Ion battery
R15,870.00
The AM-2 is our new 5.5KWh 51Volt Lithium pack designed to be easily wallmounted or shelf installed in a standard rack.Specification: 51V 5.5KWh
Rating: 1C
Parallel: up to 15 units per string
Extras: Battery Link & DC cables included
CAN Bus: Yes
RIOT Cloudlink Ready: Yes• Advanced BMS with current limiting function
• CAN Bus, fully integrates and communicates with leading Inverter brands
• Excellent high temperature performance
• High Cycle Life and Service Life
• RIOT integration ready for cloud monitoring
• 1C High Performance Lithium battery
• High Energy Density and conversion efficiency
• Complete with integrated Battery Management System
• Compatible with most Inverters and chargers
• Low self discharge
• Easy wall mount or shelf rack installation
• Heavy duty side handles for easy handling and mounting on the wall
• Built in protection for over-charge, over-discharge & over-temperatureMultiplus 24/800/16-16
R9,014.24
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectBlue Smart IP65 Charger 24 V 5A
R2,048.04
Input voltage 230 VAC
Efficiency 95%
Standby power consumption 0,5 W
Minimum battery voltage Starts charging from down to 0V
Charge voltage ‘absorption’ Normal: 28,8 V
High: 29,4 V
Li-ion: 28,4 V
Charge voltage ‘float’ Normal: 27,6 V
High: 27,6 V
Li-ion: 27,0 V
Charge voltage ‘storage’ Normal: 26,4 V
High: 26,4 V
Li-ion: 27,0 V
Charge current 5A
Low current mode 2 A
Temperature compensation 32 mV/ºC
(lead-acid batteries only)
Can be used as power supply Yes
Back current drain 0,7 Ah/month (1 mA)
Protection Reverse polarity Output short circuit
Over temperature
Operating temp. range -40 to +60°C (full rated output up to 30°C)
(cables retain flexibility at low temperature)
Humidity (non-condensing) Max 95%
ENCLOSURE
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with
CEE 7/7, BS 1363 plug (UK) or AS/NZS 3112 plug
Protection category IP65 (splash and dust proof)
Weight IP65 12V 25A 24V 13A: 1,9kg
Other: 0,9kg
Dimensions (h x w x d)
24V 5A: 47x95x190mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2,EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Shop Grid- 4 ColumnsMarketing2021-03-01T16:55:57+02:00