Protea LiFePO4 Battery 5.3kwh 51.2V
R16,215.00
44% Off
Main Features:
Plus/minus 15 years Design Life
Excellent Charging and Discharging
Integrated Battery Management System (BMS)
with current limiting functionBuilt in protection against over-charge,
over-discharge and over-heating.Low Self Discharge rate
High Energy Density and conversion efficiency
Great performance at high temperatures
CAN Bus port & battery link ports seamlessly
communicate with leading inverter brandsSimple & neat wall mount installation
CE and UN38.3 Certified.
BlueSmart IP22 Charger 12/20(1) 230V CEE 7/7
R2,908.93
Input voltage range 180 – 265 VAC
Charge current, normal mode 20A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 1
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
EasySolar 48/5000/70 MPPT 150/100 Color Control
R59,831.30
The all-in-one solar power solution
The EasySolar combines a MPPT solar charge controller, an inverter/charger and AC distribution
in one enclosure.
The product is easy to install, with a minimum of wiring.
Color Control panel
Two outstanding functions:
– Prioritizes battery charging by the MPPT charge controller
– Connects to the internet, enabling remote monitoring (VRM website) and remote control.
AC distribution
The AC distribution consists of a RCD (30mA / 63A) and four AC outputs protected by two 10A
and two 16A circuit breakers.
An additional 16A output is controlled by the AC input: it will switch on only when AC is available.
PowerAssist
Unique PowerAssist technology protects the utility or generator supply from being overloaded
by adding extra inverter power when neededEdge-lit Panel 40W LED 600 x 600 Flicker Free 3 Year Warranty
Description
- Perfect for schools, offices and hospitals, this luminaire comes with a high power factor of 0.9 and an EMC certified isolated driver
- The flicker free and low unified-glare rating are excellent for eye-comfort and productivity during long working hours.
- The aluminium frame and slimline design allow for installations in tight ceiling spaces and the option of suspending or surface mounting the luminaire.
- Tested with Tridonic Drivers, the LED isolated power supply makes for easier installation, better heat control and allows for DALI-dimming.
- This product comes with a 5-year warranty, reliable testing has rated the luminaire with up to 50 000 burning hours.
Geyserwise 200L PV Waterheating System Installed With COC
The system makes use of photovoltaic technology and a unique PTC AC/DC element to heat the water
in the geyser. This differs from the traditional thermal hot water systems where water is cycled from a
collector through pipes to the hot water cylinder by either making use of a 220V pump, 12V pump or
thermo siphoning.
Advantages over thermal hot water systems are as follows:
Any existing geyser can be converted
No Additional plumbing is required
No pumps necessary to circulate water
No risk of damaged panels in frost prone areas
The water temperature can be controlled on very hot summer days – reduced risk of overheating
problems
Suitable in all water conditions
Suitable in areas where the geyser is not situated near the panels
Modular system – can be expanded to build off-grid power system for the homeMultiplus 24/800/16-16
R9,014.24
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectGeyserwise 150L PV Waterheating System Installed With COC
The system makes use of photovoltaic technology and a unique PTC AC/DC element to heat the water
in the geyser. This differs from the traditional thermal hot water systems where water is cycled from a
collector through pipes to the hot water cylinder by either making use of a 220V pump, 12V pump or
thermo siphoning.
Advantages over thermal hot water systems are as follows:
Any existing geyser can be converted
No Additional plumbing is required
No pumps necessary to circulate water
No risk of damaged panels in frost prone areas
The water temperature can be controlled on very hot summer days – reduced risk of overheating
problems
Suitable in all water conditions
Suitable in areas where the geyser is not situated near the panels
Modular system – can be expanded to build off-grid power system for the homeMultiplus 12/500/20-16
R7,501.58
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connect
Shop Grid- 4 ColumnsMarketing2021-03-01T16:55:57+02:00











