Multiplus 12/1200/50-16
R12,990.84
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectMultiplus 24/5000/120-100
R33,826.79
21% Off
Multifunctional, with intelligent power management
The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge
technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the
MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of
a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output (second output available on models rated at
3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide
15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three
strings of six parallel units a 45 kW / 54 kVA three phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30 kW / 36 kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore
current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus
preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will
make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software.
The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage
for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger
datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second
battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go.
If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even
parallel and 3-phase operation can be programmed with DIP switches: no computer needed!
Alternatively, VE.Net can be used instead of the DIP switches.
And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several
new, advanced, featuresVictron Energy SmartSolar MPPT 250/85-Tr Solar Charge Controller
R9,265.09
41% Off
Victron Energy 85A MPPT Solar Charge Controller
A solar charger gathers energy from your solar panels, and stores it in your batteries. Using the latest, fastest technology, SmartSolar maximizes this energy-harvest, driving it intelligently to achieve full charge in the shortest possible time. SmartSolar maintains battery health, extending its life.
By constantly monitoring the voltage and current output of your solar (PV) panels, MPPT technology ensures that every drop of available power is rinsed out of your panels, and harvested for storage. The advantage of this is most noticeable when the sky is partially clouded, and light intensity is constantly changing.
Remotely control and monitor the extensive features of your SmartSolar MPPT charger with built-in Bluetooth by pairing it with your smartphone or other device via VictronConnect. If your installation is connected to the internet Victron Remote Management Portal (VRM) provides access to the full power of your MPPT, anytime, anywhere; both services are free to use. For remote installations – even when there is no internet connection or phone signal nearby – you may be able to monitor your MPPT by Bluetooth-pairing with a LoRaWAN (long-range wide area network) device, available optionally.
By adding the SmartSolar Control Display you will be able to check the status of your Charger and battery-storage at a glance. Simply plug it into the face of your MPPT charger to provide you with real-time monitoring and set-up capabilities.
RCT Axpert MAX 8kVA 8kW 48V Hybrid Inverter
R21,503.74
Features
- Customizable status LED bar with RGB breathing lights.
- Built-in Wi-Fi for mobile monitoring (Android/iOS App is available).
- Supports USB On-the-Go function.
- Reserved communication port for BMS (RS485, CAN-BUS or RS232).
- Replaceable fan design for ease of maintenance.
- Battery independency design enhances this inverter to operate without a battery connected provided there is a grid connection.
- Enhanced AC/Solar charger to 120A.
- Built-in anti-dust kit.
- Parallel operation up to 6 units.
Multiplus 24/800/16-16
R9,014.24
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connect
Shop Grid- 4 ColumnsMarketing2021-03-01T16:55:57+02:00