Blue Smart IP67 Charger 12/17
R2,491.62
Input voltage range and frequency 180-265 VAC 45-65 Hz
Efficiency 95%
No load power consumption 0.5W
Charge voltage ‘absorption’ Normal: 14,4V
High: 14,7V
Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V
High: 13,8V
Li-ion: 13,5V
Charge voltage ‘storage’ Normal: 13,2V
High: 13,2V
Li-ion: 13,5V
Charge current, normal mode 17A
Charge current, LOW 6A
Charge algorithm 5-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +60°C (full rated output up to 40°C) Derate 3% per °C above 40°C
Humidity Up to 100%
Start interrupt option (Si) Short circuit proof, current limit 0,5 A
(12/25 and 24/12 models only) Output voltage: max one volt lower than main output
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection Black and red cable of 1,5 meter
230 V AC-connection Cable of 1,5 meter with CEE 7/7 plug
Protection category IP67
Weight (kg) 2,4
Dimensions (h x w x d in mm) 99 x 219 x 65
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission Immunity EN 55014-1, EN 61000-6-3, EN 61000-3-2
Automotive Directive EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
GROTHEN DC 7.5W 12V Dosing Pump Peristaltic Pump Mini Water Liquid Pump
R230.00
Features: Pump head adopts buckle design without screw, which can be removed through pressing the buckles on both sides with your hands, easy to clean and maintain. Support CW and CCW: Switching power supply positive and negative pole, realize the CW and CCW of the pump head. Flow direction: You can control the flow direction by the positive and negative connect. No valves and seals, convenient hose replacement, easy maintenance. This small dosing pump has the function of self-priming. Widely used in the field of experiment, medical, biochemical analysis, pharmaceuticals, fine chemicals, biotechnology, food, environmental protection, family, etc.
BlueSmart IP22 Charger 12/20(1) 230V CEE 7/7
R2,908.93
Input voltage range 180 – 265 VAC
Charge current, normal mode 20A
Charge current, NIGHT or LOW 7,5 / 10 / 15 A
Efficiency 93%
No load power consumption 0.5 W
Frequency 45 – 65 Hz
Number of outputs 1
Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V
Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge algorithm 6-stage adaptive
Can be used as power supply Yes
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range -20 to +50°C
Humidity (non-condensing) Max 98%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery connection Screw terminals 13 mm² / AWG6
230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
Protection category IP22
Weight 1,3 kg
Dimensions (h x w x d) 235 x 108 x 65 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Automotive E4-10R
Venus GX
R4,021.44
27% Off
Panels and system monitoring
The Venus GX is the communication-centre of your installation.
Venus allows you to talk to all components in your system and ensure they are working in harmony.
Monitoring of live data, and changing settings is performed by using your smartphone (or other device) via our free-to-use Victron Remote Management Portal (VRM).
Multiplus 12/800/35-16
R9,313.24
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connect