Shop Grid – 3 Columns2021-03-01T16:11:38+02:00
  • Multiplus 24/3000/70-50

    R20,987.50

    27% Off

    Multiplus, Multifunctional, with intelligent power management

    The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.

    Two AC Outputs

    The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).

    Virtually unlimited power thanks to parallel operation

    Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.

    Three phase capability

    In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.

    Split phase options

    Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.

    PowerControl – Dealing with limited generator, shoreside or grid power

    The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

    PowerAssist – Boosting the capacity of shore or generator power

    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

    Four stage adaptive charger and dual bank battery charging

    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.

    System configuring has never been easier

    After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.

    View product
  • Multiplus 24/3000/70-16

    R19,186.37

    28% Off

    Multiplus, Multifunctional, with intelligent power management

    The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.

    Two AC Outputs

    The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).

    Virtually unlimited power thanks to parallel operation

    Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.

    Three phase capability

    In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.

    Split phase options

    Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.

    PowerControl – Dealing with limited generator, shoreside or grid power

    The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

    PowerAssist – Boosting the capacity of shore or generator power

    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

    Four stage adaptive charger and dual bank battery charging

    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.

    System configuring has never been easier

    After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.

    View product
  • Multiplus 24/1200/25-16

    R12,990.84

    PowerControl / PowerAssist Yes
    Three Phase and parallel operation Yes
    Transfer switch 16A
    INVERTER
    Input voltage range 9,5 – 17V 19 – 33V 38– 66V
    Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
    Cont. output power at 25°C (3) 1200VA
    Cont. output power at 25°C 1000W
    Cont. output power at 40°C 900W
    Cont. output power at 65°C 600W
    Peak power 2400W
    Maximum efficiency 93 / 94 / 95%
    Zero-load power 10 / 9 / 10W
    Zero-load power in search mode 3/ 3 / 3W
    CHARGER
    AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
    Charge voltage ‘absorption’ 14,4 / 28,8 / 57,6V
    Charge voltage ‘float’ 13,8 / 27,6 / 55,2V
    Storage mode 13,2 / 26,4 /52,8V
    Charge current house battery (4) 50 / 25 / 13A
    Charge current starter battery 1A (12V and 24V models only)
    Battery temperature sensor Yes
    GENERAL
    Programmable relay (5) Yes
    Protection (2) a – g
    VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
    (RJ45-spliter ASS030065510 needed for 500/800/12ooVA models)
    Remote on-off On/off/charger only On/off
    DIP switches Yes (6) Yes (3)
    Internal DC fuse 200/100/50A
    Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
    Humidity (non-condensing): max 95%
    ENCLOSURE
    Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
    Battery-connection 35 / 25 / 10 mm²
    230V AC-connection G-ST18i connector
    Weight 8,2 kg
    Dimensions (h x w x d) 406 x 250 x 100 mm
    STANDARDS
    Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
    Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
    IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
    Road vehicles ECE R10-5
    1) Can be adjusted to 60Hz and to 240V
    2) Protection
    a. Output short circuit
    b. Overload
    c. Battery voltage too high
    d. Battery voltage too low
    e. Temperature too high
    f. 230VAC on inverter output
    g. Input voltage ripple too high
    3) Non-linear load, crest factor 3:1
    4) At 25°C ambient
    5) Programmable relay which can be set for:
    general alarm, DC under voltage or generator start/stop signal function
    AC rating: 230V/4A
    DC rating: 4A up to 35VDC, 1A up to 60VDC

    View product
  • Multiplus 12/800/35-16

    R9,313.24

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Multiplus 12/500/20-16

    R7,501.58

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Multiplus 12/3000/120-50

    R23,007.13

    20% Off

    Multiplus, Multifunctional, with intelligent power management

    The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.

    Two AC Outputs

    The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).

    Virtually unlimited power thanks to parallel operation

    Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.

    Three phase capability

    In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.

    Split phase options

    Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.

    PowerControl – Dealing with limited generator, shoreside or grid power

    The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

    PowerAssist – Boosting the capacity of shore or generator power

    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

    Four stage adaptive charger and dual bank battery charging

    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.

    System configuring has never been easier

    After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.

    View product
  • Multiplus 12/1200/50-16

    R12,990.84

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Multi-function Triangle Signal Warning Light Portable COB LED Work Light Flood Lamp SOS Camping Searchlight LED Traffic Lighting

    R253.00

    Feature:
    Plastic shell wrapped in a layer of carbon black, feel good, non-slip.
    Come with magnet and hook, Folding design, easy to use in a small space inside.
    High COB LED,Low COB LED ,red led ,red sos led ,4-different lighting modes to meet your lighting needs.
    LED bulbs, green energy saving and environmental protection, the use of longer time.
    AA OR 18650 battery, you can use the USB cable to charge.

    Product parameters:

    4-mode: high/ low/ red/red sos
    Size: 210 x 210 mm
    Weight: 500g
    Power supply: 4pcs aa or 2 pcs 18650 battery

    Package Included:
    1 x LED light

    2 pcs 18650 battery

    View product
  • Mini Brushless Water Pump Amphibious 6V-12V Submersible Pump W/Cable

    R379.99

    View product
  • Mecer 3kW 24V 1200W PWM Off Grid Pure Sine Wave Inverter

    R5,980.00

    View product
  • Mecer 1000W Pure Sine Wave 12V Inverter – 600W (PWM) Solar Controller

    R4,485.00

    View product
  • MC4 Inline Male Cable OD 3mm-6mm

    R17.25

    36% Off

    MC Type 4 Male Plug 600V Dc

    View product

Title

Go to Top