Shop Grid- 4 Columns2021-03-01T16:55:57+02:00
  • Multiplus 48/800/9-16

    R9,807.59

    PowerControl / PowerAssist Yes
    Three Phase and parallel operation Yes
    Transfer switch 16A
    INVERTER
    Input voltage range 9,5 – 17V 19 – 33V 38– 66V
    Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
    Cont. output power at 25°C (3) 800VA
    Cont. output power at 25°C 700W
    Cont. output power at 40°C 650W
    Cont. output power at 65°C 400W
    Peak power 1600W
    Maximum efficiency 92 / 93 / 94%
    Zero-load power 7 / 7 / 8W
    Zero-load power in search mode 2 / 2 / 3W
    CHARGER
    AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
    Charge voltage ‘absorption’ 14,4 / 28,8 / 57,6V
    Charge voltage ‘float’ 13,8 / 27,6 / 55,2V
    Storage mode 13,2 / 26,4 /52,8V
    Charge current house battery (4) 35 / 16 / 9A
    Charge current starter battery 1A (12V and 24V models only)
    Battery temperature sensor Yes
    GENERAL
    Programmable relay (5) Yes
    Protection (2) a – g
    VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
    (RJ45-spliter ASS030065510 needed for 500/800/12ooVA models)
    Remote on-off On/off/charger only On/off
    DIP switches Yes (6) Yes (3)
    Internal DC fuse 150/80/40A
    Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
    Humidity (non-condensing): max 95%
    ENCLOSURE
    Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
    Battery-connection 25 / 16 / 10 mm²
    230V AC-connection G-ST18i connector
    Weight 6,4 kg
    Dimensions (h x w x d) 360 x 240 x 100 mm
    STANDARDS
    Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
    Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
    IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
    Road vehicles ECE R10-5
    1) Can be adjusted to 60Hz and to 240V
    2) Protection
    a. Output short circuit
    b. Overload
    c. Battery voltage too high
    d. Battery voltage too low
    e. Temperature too high
    f. 230VAC on inverter output
    g. Input voltage ripple too high
    3) Non-linear load, crest factor 3:1
    4) At 25°C ambient
    5) Programmable relay which can be set for:
    general alarm, DC under voltage or generator start/stop signal function
    AC rating: 230V/4A
    DC rating: 4A up to 35VDC, 1A up to 60VDC

    View product
  • 10W Atlas Surge Protected LED Flood Light AC220V 900 Lumens

    R103.16

    Features and Benefits
    Discreet but powerful and long lasting, this floodlight is perfectly suited for commercial and repetitive usage,
    but will also be at home in your residence or garden.
    The younger brother of the Elite, this floodlight is by no means little, with a massive 1KV or 2KV surge
    protection in a compact driver-on-board housing.
    The design allows for auto-production which provides a truly stable, reliable and cost effective solution to
    the floodlight market.
    Using the newest technology, the Mesmerize Atlas range implements excellent weatherproofing and
    ventilation functions called ePTEF technology.
    As with most of the Mesmerize Floodlights, the Atlas comes with a 1meter H05-graded cable and an
    oblique angled bracket for even easier and faster installations.
    It is rated up to 25 000 hours of life and has up to 100 lumens per watt, this product carries a 2 Year Warranty.

     

    View product
  • 30A In-line MC4 PV Solar Fuse Holder Cable Connector

    R89.70

    This high quality IP67 rated connector is designed to protect solar panels from current backflow.

    This is a recommended investment to protect your valuable investment in solar panels.

    Feature:

    -30A in-line Diode Connector Solar Panel Cable Connectors

    – Practical connector used between Solar panel and switch box to prevent the reversal of current.

    – Contacts for the connector are copper, coated with tin for easy solder adhesion. Each end nuts comes with rubber bushings for air tightening.

    – This MC4 connector is rated as IP67. IP (Ingress Protection) ratings the first numeral refers to the level of dust resistance and the second numeral refers to the level of water resistance.

    – Diode built in the connector

    – TUV-approved Connector head

    View product
  • Multiplus 12/1200/50-16

    R12,990.84

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • EasySolar 24/1600/40-16 MPPT 100/50

    R25,250.12

    All-in-one solar power solution
    The EasySolar combines a MPPT solar charge controller, an inverter/charger and AC distribution in
    one enclosure.
    The product is easy to install, with a minimum of wiring.
    The solar charge controller: Blue Solar MPPT 100/50
    Up to three strings of PV panels can be connected to three sets of MC4 (PV-ST01) PV connectors.
    The inverter/charger: MultiPlus Compact 12/1600/70 or 24/1600/40
    The MPPT charge controller and the MultiPlus Compact inverter/charger share the DC battery
    cables (included). The batteries can be charged with solar power (BlueSolar MPPT) and/or with AC
    power (inverter/charger) from the utility grid or a genset.
    AC distribution
    The AC distribution consists of a RCD (30 mA/16 A) and four AC outputs protected by two 10A and
    two 16A circuit breakers.
    One 16A output is controlled by the AC input: it will switch on only when AC is available.
    PowerAssist
    Unique PowerAssist technology protects the utility or generator supply from being overloaded by
    adding extra inverter power when needed

    View product
  • Quattro 48/10000/140-100/100

    R43,493.35

    37% Off

    Two AC inputs with integrated transfer switch
    The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
    generators. The Quattro will automatically connect to the active source.
    Two AC Outputs
    The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
    grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
    the battery, like a water heater for example, can be connected to this output.
    Virtually unlimited power thanks to parallel operation
    Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
    power and 840 Amps charging capacity.
    Split phase options
    Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
    phase, to supply up to 30kW / 36kVA of split phase power.
    Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
    www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
    Three phase capability
    Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
    connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
    supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
    account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
    being overloaded.
    PowerAssist – Boosting shore or generator power
    This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
    capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
    make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
    the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
    a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
    Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
    tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
    be changed remotely

    View product
  • KBE Solar cable 4mm – Red Triple Certified

    R14.72

    17% Off

    View product
  • BlueSmart IP22 Charger 12/30(3) 230V CEE 7/7

    R3,951.92

    Input voltage range 180 – 265 VAC

    Charge current, normal mode 30A

    Charge current, NIGHT or LOW 7,5 / 10 / 15 A

    Efficiency 93%

    No load power consumption 0.5 W

    Frequency 45 – 65 Hz

    Number of outputs 3

    Charge voltage ‘absorption’ Normal 14,4V High: 14,7V Li-ion: 14,2V

    Charge voltage ‘float’ Normal: 13,8V High: 13,8V Li-ion: 13,5V

    Charge voltage ‘storage ‘ Normal: 13,2V High: 13,2V Li-ion: 13,5V

    Charge algorithm 6-stage adaptive

    Can be used as power supply Yes

    Protection Battery reverse polarity (fuse) Output short circuit Over temperature

    Operating temp. range -20 to +50°C

    Humidity (non-condensing) Max 98%

     

    ENCLOSURE

    Material & Colour Aluminium (blue RAL 5012)

    Battery connection Screw terminals 13 mm² / AWG6

    230 V AC connection Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)

    Protection category IP22

    Weight 1,3 kg

    Dimensions (h x w x d) 235 x 108 x 65 mm

     

    STANDARDS

    Safety EN 60335-1, EN 60335-2-29

    Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2

    Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3

    Automotive E4-10R

    View product
  • Multiplus 12/500/20-16

    R7,501.58

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Multiplus 48/500/6-16

    R7,195.27

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Growatt SPF 5000 ES Hybrid Inverter 48V

    R10,235.00

    The Growatt SPF 5000 ES 5kVA 5.5kW 48V Hybrid Inverter is a multi-functional off grid solar inverter, integrated with a MPPT solar charge controller, a high frequency pure sine wave inverter with a UPS function module all in one machine. This unit is perfect for off grid backup power and self-consumption applications. The Growatt SPF 5000 ES Hybrid Inverter can be used with or without a battery. Growatt 5kW inverters are extensively used worldwide for applications in residential, commercial, utility-scale scenarios as well as other storage power station projects.?

    View product
  • 8L Eco-Dew Gas Geyser

    The 8l Dewhot Ecodew white powder coated gas water heater is suitable for a shower and wash hand basin application. It will also be ideal for camping, off road trailers and hairdressing salons providing continuous hot water. This unit is suitable for outdoor installation only.

    TYPE D
    For outdoor use under a cover with a flue.

    Features

    • Requires no electricity – flame ignition and geyser function are battery operated
    • 84% energy efficiency
    • Neat and compact
    • Stainless steel cover
    • LCD temperature display
    • Flame failure safety device
    • Anti-freeze function
    View product