Victron Phoenix Inverters

  • Phoenix 12/1200 ve.direct schuko

    R6,751.32

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 12/250 ve.direct schuko

    R1,756.42

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 12/375 ve.direct schuko

    R2,269.17

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 12/500 ve.direct schuko

    R2,817.82

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 12/800 ve.direct schuko

    R5,122.86

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 24/1200 ve.direct schuko

    R6,751.32

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 24/250 ve.direct schuko

    R1,756.42

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 24/375 ve.direct schuko

    R2,269.17

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 24/500 ve.direct schuko

    R2,817.82

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 24/800 ve.direct schuko

    R5,122.86

    Cont. power at 25 degree celcius(1): 800VA

    Cont. power at 25/40 degree celcuis: 650/560W

    Peak power: 1500W

    Output AC voltage/frequency(adjustable): 230VAC or 120VAC +/-3% 50Hz or 60Hz +-.01%

    Input voltage range: 9,2-17/18,4-34,0/36,8-62,0V

    DC low shut down(adjustable): 9,3/18,6/37,2V

    Dynamic(load dependant) DC low shut down(fully configurable): https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff

    DC low restart and alarm(adjustable): 10,9/21,8/43,6V

    Battery charged detect(adjustable): 14,0/28,0/56,0V

    Max efficiency: 90/90/91%

    Zero-load power: 6,5/7/9,5W

    Default zero-load power in ECO mode(default retry interval:2,5s,adjustable: 1/1,5/3,0W

    ECO mode stop and start power setting: Adjustable

    Protection(2): a-f

    Operating temperature range: -40 to +65 degree celcius(fan assisted cooling) Derate 1,25% per degree celcuis above 40 degree celsius

    Humidity(non-condensing) max 95%

    Enclosure:

    Material & Colour: Steel chassis and plastic cover (blue Ral 5012)

    Battery-connection: Screw terminals

    Maximuim cable cross section: 10mm2 / AWG8

    Standard AC outlets: 230V: Schuko(CEE 7/4). IEC-320(male plug included) UK(BS 1363), AU/NZ (AS/NZS 3112) 120V:Nema 5-15R

    Protection category: IP21

    Weight: 5,5kg/5,12lbs

    Dimensions(mm) 105x216x305

    Accessries:

    Remote on-off: Yes

    Automatic transfer switch: Filax

    Standards:

    Safety: EN-IEC 60335-1 / EN-IEC 62109-1

    EMC: EN 55014-1/ EN55014-2 / IEC6100-6-1 / IEC6100-6-2 / IEC6100-6-3

    Automatic Directive: ECE R10-4

    • Nonlinear load, crest factor 3:1
    • Protection key:
    • a) output short circuit
    • b) overload
    • c) battery voltage too high
    • d) battery voltage too low
    • e) temperature too high
    • f) DC ripple too high
    View product
  • Phoenix 48/250 ve.direct schuko

    R2,049.14

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 48/500 ve.direct schuko

    R3,696.02

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 48/800 ve.direct schuko

    R5,489.27

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix Inverter 48/3000

    R20,346.04

    SinusMax – Superior engineering
    Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
    The design criteria have been to produce a true sine wave inverter with optimised efficiency but without
    compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
    dimensions, light in weight and capable of supplying power, problem-free, to any load.

    Extra start-up power
    A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
    technology does not offer such extreme performance. Phoenix inverters, however, are well suited to power up
    difficult loads such as refrigeration compressors, electric motors and similar appliances.

    Virtually unlimited power thanks to parallel and 3-phase operation capability
    Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
    will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.

    To transfer the load to another AC source: the automatic transfer switch
    If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
    switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
    other electronic equipment will continue to operate without disruption because the MultiPlus features a very
    short switchover time (less than 20 milliseconds).

    Computer interface
    All models have a RS-485 port. All you need to connect to your PC is our MK2 interface (see under accessories).
    This interface takes care of galvanic isolation between the inverter and the computer, and converts from RS-485
    to RS-232. A RS-232 to USB conversion cable is also available. Together with our VEConfigure software, which
    can be downloaded free of charge from our website, all parameters of the inverters can be customised. This
    includes output voltage and frequency, over and under voltage settings and programming the relay. This relay
    can for example be used to signal several alarm conditions, or to start a generator. The inverters can also be
    connected to VENet, the new power control network of Victron Energy, or to other computerised monitoring
    and control systems.

    New applications of high power inverters
    The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
    calculations please refer to our book “Energy Unlimited” (available free of charge from Victron Energy and
    downloadable from www.victronenergy.com

    View product
  • VICTRON PHOENIX 24/5000 INVERTER

    R35,587.64

    Developed by inverter specialists Victron for professional duty, the Phoenix range of inverters are suitable for the widest range of applications. Developed to produce a true sine wave inverter with optimized efficiency but without compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact dimensions, light in weight and capable of supplying power, problem-free, to any load.

    Using SinusMax technology allows the Phoenix to supply very high start-up power. Conventional high-frequency technology does not offer such extreme performance. Phoenix inverters, however, are well suited to power up difficult loads such as refrigeration compressors, electric motors and similar appliances.

    • SinusMax – Superior engineering
    • Extra start-up power
    • To transfer the load to another AC source: the automatic transfer switch
    View product
  • VICTRON PHOENIX COMPACT 12/1200 INVERTER

    R11,582.41

    SinusMax – Superior engineering
    Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
    The design criteria have been to produce a true sine wave inverter with optimized efficiency but without
    compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
    dimensions, light in weight and capable of supplying power, problem-free, to any load.
    Extra start-up power
    A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
    technology does not offer such extreme performance. Phoenix Inverters, however, are well suited to power up
    difficult loads such as refrigeration compressors, electric motors and similar appliances.
    Virtually unlimited power thanks to parallel and 3-phase operation capability
    Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
    will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.
    To transfer the load to another AC source: the automatic transfer switch
    If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
    switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
    other electronic equipment will continue to operate without disruption because the MultiPlus features a very
    short switchover time (less than 20 milliseconds).
    Computer interface
    All models have a RS-485 port. All you need to connect to your PC is our MK3-USB VE.Bus to USB interface
    (see under accessories). Together with our VEConfigure software, which can be downloaded free of charge from
    our website, all parameters of the inverters can be customized. This includes output voltage and frequency, over
    and under voltage settings and programming the relay. This relay can for example be used to signal several
    alarm conditions, or to start a generator. The inverters can also be connected to VENet, the new power control
    network of Victron Energy, or to other computerized monitoring and control systems.
    New applications of high power inverters
    The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
    calculations please refer to our book ‘Energy

    View product
  • VICTRON PHOENIX COMPACT 12/1600 INVERTER

    R14,124.94

    SinusMax – Superior engineering
    Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
    The design criteria have been to produce a true sine wave inverter with optimized efficiency but without
    compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
    dimensions, light in weight and capable of supplying power, problem-free, to any load.
    Extra start-up power
    A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
    technology does not offer such extreme performance. Phoenix Inverters, however, are well suited to power up
    difficult loads such as refrigeration compressors, electric motors and similar appliances.
    Virtually unlimited power thanks to parallel and 3-phase operation capability
    Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
    will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.
    To transfer the load to another AC source: the automatic transfer switch
    If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
    switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
    other electronic equipment will continue to operate without disruption because the MultiPlus features a very
    short switchover time (less than 20 milliseconds).
    Computer interface
    All models have a RS-485 port. All you need to connect to your PC is our MK3-USB VE.Bus to USB interface
    (see under accessories). Together with our VEConfigure software, which can be downloaded free of charge from
    our website, all parameters of the inverters can be customized. This includes output voltage and frequency, over
    and under voltage settings and programming the relay. This relay can for example be used to signal several
    alarm conditions, or to start a generator. The inverters can also be connected to VENet, the new power control
    network of Victron Energy, or to other computerized monitoring and control systems.
    New applications of high power inverters
    The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
    calculations please refer to our book ‘Energy

    View product
  • VICTRON PHOENIX COMPACT 12/2000 INVERTER

    R15,955.02

    SinusMax – Superior engineering
    Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
    The design criteria have been to produce a true sine wave inverter with optimized efficiency but without
    compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
    dimensions, light in weight and capable of supplying power, problem-free, to any load.
    Extra start-up power
    A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
    technology does not offer such extreme performance. Phoenix Inverters, however, are well suited to power up
    difficult loads such as refrigeration compressors, electric motors and similar appliances.
    Virtually unlimited power thanks to parallel and 3-phase operation capability
    Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
    will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.
    To transfer the load to another AC source: the automatic transfer switch
    If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
    switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
    other electronic equipment will continue to operate without disruption because the MultiPlus features a very
    short switchover time (less than 20 milliseconds).
    Computer interface
    All models have a RS-485 port. All you need to connect to your PC is our MK3-USB VE.Bus to USB interface
    (see under accessories). Together with our VEConfigure software, which can be downloaded free of charge from
    our website, all parameters of the inverters can be customized. This includes output voltage and frequency, over
    and under voltage settings and programming the relay. This relay can for example be used to signal several
    alarm conditions, or to start a generator. The inverters can also be connected to VENet, the new power control
    network of Victron Energy, or to other computerized monitoring and control systems.
    New applications of high power inverters
    The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
    calculations please refer to our book ‘Energy

    View product
  • VICTRON PHOENIX COMPACT 24/1200 INVERTER

    R11,582.41

    SinusMax – Superior engineering
    Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
    The design criteria have been to produce a true sine wave inverter with optimized efficiency but without
    compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
    dimensions, light in weight and capable of supplying power, problem-free, to any load.
    Extra start-up power
    A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
    technology does not offer such extreme performance. Phoenix Inverters, however, are well suited to power up
    difficult loads such as refrigeration compressors, electric motors and similar appliances.
    Virtually unlimited power thanks to parallel and 3-phase operation capability
    Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
    will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.
    To transfer the load to another AC source: the automatic transfer switch
    If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
    switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
    other electronic equipment will continue to operate without disruption because the MultiPlus features a very
    short switchover time (less than 20 milliseconds).
    Computer interface
    All models have a RS-485 port. All you need to connect to your PC is our MK3-USB VE.Bus to USB interface
    (see under accessories). Together with our VEConfigure software, which can be downloaded free of charge from
    our website, all parameters of the inverters can be customized. This includes output voltage and frequency, over
    and under voltage settings and programming the relay. This relay can for example be used to signal several
    alarm conditions, or to start a generator. The inverters can also be connected to VENet, the new power control
    network of Victron Energy, or to other computerized monitoring and control systems.
    New applications of high power inverters
    The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
    calculations please refer to our book ‘Energy

    View product
  • VICTRON PHOENIX COMPACT 24/1600 INVERTER

    R14,124.93

    SinusMax – Superior engineering
    Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
    The design criteria have been to produce a true sine wave inverter with optimized efficiency but without
    compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
    dimensions, light in weight and capable of supplying power, problem-free, to any load.
    Extra start-up power
    A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
    technology does not offer such extreme performance. Phoenix Inverters, however, are well suited to power up
    difficult loads such as refrigeration compressors, electric motors and similar appliances.
    Virtually unlimited power thanks to parallel and 3-phase operation capability
    Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
    will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.
    To transfer the load to another AC source: the automatic transfer switch
    If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
    switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
    other electronic equipment will continue to operate without disruption because the MultiPlus features a very
    short switchover time (less than 20 milliseconds).
    Computer interface
    All models have a RS-485 port. All you need to connect to your PC is our MK3-USB VE.Bus to USB interface
    (see under accessories). Together with our VEConfigure software, which can be downloaded free of charge from
    our website, all parameters of the inverters can be customized. This includes output voltage and frequency, over
    and under voltage settings and programming the relay. This relay can for example be used to signal several
    alarm conditions, or to start a generator. The inverters can also be connected to VENet, the new power control
    network of Victron Energy, or to other computerized monitoring and control systems.
    New applications of high power inverters
    The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
    calculations please refer to our book ‘Energy

    View product
  • VICTRON PHOENIX COMPACT 24/2000 INVERTER

    R15,955.02

    SinusMax – Superior engineering
    Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
    The design criteria have been to produce a true sine wave inverter with optimized efficiency but without
    compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
    dimensions, light in weight and capable of supplying power, problem-free, to any load.
    Extra start-up power
    A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
    technology does not offer such extreme performance. Phoenix Inverters, however, are well suited to power up
    difficult loads such as refrigeration compressors, electric motors and similar appliances.
    Virtually unlimited power thanks to parallel and 3-phase operation capability
    Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
    will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.
    To transfer the load to another AC source: the automatic transfer switch
    If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
    switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
    other electronic equipment will continue to operate without disruption because the MultiPlus features a very
    short switchover time (less than 20 milliseconds).
    Computer interface
    All models have a RS-485 port. All you need to connect to your PC is our MK3-USB VE.Bus to USB interface
    (see under accessories). Together with our VEConfigure software, which can be downloaded free of charge from
    our website, all parameters of the inverters can be customized. This includes output voltage and frequency, over
    and under voltage settings and programming the relay. This relay can for example be used to signal several
    alarm conditions, or to start a generator. The inverters can also be connected to VENet, the new power control
    network of Victron Energy, or to other computerized monitoring and control systems.
    New applications of high power inverters
    The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
    calculations please refer to our book ‘Energy

    View product

Filter by price