EasySolar 12/1600/70-16 MPPT 100/50
R25,249.81
All-in-one solar power solution
The EasySolar combines a MPPT solar charge controller, an inverter/charger and AC distribution in
one enclosure.
The product is easy to install, with a minimum of wiring.
The solar charge controller: Blue Solar MPPT 100/50
Up to three strings of PV panels can be connected to three sets of MC4 (PV-ST01) PV connectors.
The inverter/charger: MultiPlus Compact 12/1600/70 or 24/1600/40
The MPPT charge controller and the MultiPlus Compact inverter/charger share the DC battery
cables (included). The batteries can be charged with solar power (BlueSolar MPPT) and/or with AC
power (inverter/charger) from the utility grid or a genset.
AC distribution
The AC distribution consists of a RCD (30 mA/16 A) and four AC outputs protected by two 10A and
two 16A circuit breakers.
One 16A output is controlled by the AC input: it will switch on only when AC is available.
PowerAssist
Unique PowerAssist technology protects the utility or generator supply from being overloaded by
adding extra inverter power when neededEasySolar 24/1600/40-16 MPPT 100/50
R25,250.12
All-in-one solar power solution
The EasySolar combines a MPPT solar charge controller, an inverter/charger and AC distribution in
one enclosure.
The product is easy to install, with a minimum of wiring.
The solar charge controller: Blue Solar MPPT 100/50
Up to three strings of PV panels can be connected to three sets of MC4 (PV-ST01) PV connectors.
The inverter/charger: MultiPlus Compact 12/1600/70 or 24/1600/40
The MPPT charge controller and the MultiPlus Compact inverter/charger share the DC battery
cables (included). The batteries can be charged with solar power (BlueSolar MPPT) and/or with AC
power (inverter/charger) from the utility grid or a genset.
AC distribution
The AC distribution consists of a RCD (30 mA/16 A) and four AC outputs protected by two 10A and
two 16A circuit breakers.
One 16A output is controlled by the AC input: it will switch on only when AC is available.
PowerAssist
Unique PowerAssist technology protects the utility or generator supply from being overloaded by
adding extra inverter power when neededEasySolar 24/3000/70 MPPT 150/70 Color Control
R37,051.32
The all-in-one solar power solution
The EasySolar combines a MPPT solar charge controller, an inverter/charger and AC distribution
in one enclosure.
The product is easy to install, with a minimum of wiring.
Color Control panel
Two outstanding functions:
– Prioritizes battery charging by the MPPT charge controller
– Connects to the internet, enabling remote monitoring (VRM website) and remote control.
AC distribution
The AC distribution consists of a RCD (30mA / 63A) and four AC outputs protected by two 10A
and two 16A circuit breakers.
An additional 16A output is controlled by the AC input: it will switch on only when AC is available.
PowerAssist
Unique PowerAssist technology protects the utility or generator supply from being overloaded
by adding extra inverter power when neededEasySolar 48/5000/70 MPPT 150/100 Color Control
R59,831.30
The all-in-one solar power solution
The EasySolar combines a MPPT solar charge controller, an inverter/charger and AC distribution
in one enclosure.
The product is easy to install, with a minimum of wiring.
Color Control panel
Two outstanding functions:
– Prioritizes battery charging by the MPPT charge controller
– Connects to the internet, enabling remote monitoring (VRM website) and remote control.
AC distribution
The AC distribution consists of a RCD (30mA / 63A) and four AC outputs protected by two 10A
and two 16A circuit breakers.
An additional 16A output is controlled by the AC input: it will switch on only when AC is available.
PowerAssist
Unique PowerAssist technology protects the utility or generator supply from being overloaded
by adding extra inverter power when neededMultiplus 12/1200/50-16
R12,990.84
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectMultiplus 12/3000/120-50
R28,725.83
Multiplus, Multifunctional, with intelligent power management
The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shoreside or grid power
The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.
Multiplus 12/3000/120/16
R26,603.97
Multifunctional, with intelligent power management
The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge
technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the
MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of
a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output (second output available on models rated at
3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide
15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three
strings of six parallel units a 45 kW / 54 kVA three phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30 kW / 36 kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore
current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus
preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will
make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software.
The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage
for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger
datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second
battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go.
If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even
parallel and 3-phase operation can be programmed with DIP switches: no computer needed!
Alternatively, VE.Net can be used instead of the DIP switches.
And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several
new, advanced, featuresMultiplus 12/500/20-16
R7,501.58
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectMultiplus 12/800/35-16
R9,313.24
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectMultiplus 24/1200/25-16
R12,990.84
PowerControl / PowerAssist Yes
Three Phase and parallel operation Yes
Transfer switch 16A
INVERTER
Input voltage range 9,5 – 17V 19 – 33V 38– 66V
Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
Cont. output power at 25°C (3) 1200VA
Cont. output power at 25°C 1000W
Cont. output power at 40°C 900W
Cont. output power at 65°C 600W
Peak power 2400W
Maximum efficiency 93 / 94 / 95%
Zero-load power 10 / 9 / 10W
Zero-load power in search mode 3/ 3 / 3W
CHARGER
AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
Charge voltage ‘absorption’ 14,4 / 28,8 / 57,6V
Charge voltage ‘float’ 13,8 / 27,6 / 55,2V
Storage mode 13,2 / 26,4 /52,8V
Charge current house battery (4) 50 / 25 / 13A
Charge current starter battery 1A (12V and 24V models only)
Battery temperature sensor Yes
GENERAL
Programmable relay (5) Yes
Protection (2) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
(RJ45-spliter ASS030065510 needed for 500/800/12ooVA models)
Remote on-off On/off/charger only On/off
DIP switches Yes (6) Yes (3)
Internal DC fuse 200/100/50A
Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
Battery-connection 35 / 25 / 10 mm²
230V AC-connection G-ST18i connector
Weight 8,2 kg
Dimensions (h x w x d) 406 x 250 x 100 mm
STANDARDS
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles ECE R10-5
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for:
general alarm, DC under voltage or generator start/stop signal function
AC rating: 230V/4A
DC rating: 4A up to 35VDC, 1A up to 60VDCMultiplus 24/3000/70-16
R26,603.97
Multiplus, Multifunctional, with intelligent power management
The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shoreside or grid power
The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.
Multiplus 24/3000/70-50
R28,725.83
Multiplus, Multifunctional, with intelligent power management
The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shoreside or grid power
The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.
Multiplus 24/500/10-16
R7,501.58
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectMultiplus 24/5000/120-100
R42,558.99
Multifunctional, with intelligent power management
The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge
technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the
MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of
a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output (second output available on models rated at
3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide
15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three
strings of six parallel units a 45 kW / 54 kVA three phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30 kW / 36 kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore
current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus
preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will
make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software.
The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage
for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger
datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second
battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go.
If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even
parallel and 3-phase operation can be programmed with DIP switches: no computer needed!
Alternatively, VE.Net can be used instead of the DIP switches.
And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several
new, advanced, featuresMultiplus 24/800/16-16
R9,014.24
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectMultiplus 48/3000/35-16
R21,553.82
Multifunctional, with intelligent power management
The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge
technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the
MultiPlus has several advanced features, as outlined below.
Two AC Outputs
The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of
a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output (second output available on models rated at
3kVA and more).
Virtually unlimited power thanks to parallel operation
Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide
15kW / 18kVA output power with 420 Amps of charging capacity.
Three phase capability
In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three
strings of six parallel units a 45 kW / 54 kVA three phase inverter and 1260 A charger can be built.
Split phase options
Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30 kW / 36 kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore
current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus
preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will
make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Four stage adaptive charger and dual bank battery charging
The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software.
The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage
for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger
datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second
battery using an independent trickle charge output intended for a main engine or generator starter battery.
System configuring has never been easier
After installation, the MultiPlus is ready to go.
If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even
parallel and 3-phase operation can be programmed with DIP switches: no computer needed!
Alternatively, VE.Net can be used instead of the DIP switches.
And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several
new, advanced, featuresMultiplus 48/500/6-16
R7,195.27
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as
an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm
(inverter almost too hot, ripple on the input
almost too high, battery voltage almost too
low).
Remote on / off / charger on
Three pole connectMultiplus 48/800/9-16
R9,807.59
PowerControl / PowerAssist Yes
Three Phase and parallel operation Yes
Transfer switch 16A
INVERTER
Input voltage range 9,5 – 17V 19 – 33V 38– 66V
Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
Cont. output power at 25°C (3) 800VA
Cont. output power at 25°C 700W
Cont. output power at 40°C 650W
Cont. output power at 65°C 400W
Peak power 1600W
Maximum efficiency 92 / 93 / 94%
Zero-load power 7 / 7 / 8W
Zero-load power in search mode 2 / 2 / 3W
CHARGER
AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
Charge voltage ‘absorption’ 14,4 / 28,8 / 57,6V
Charge voltage ‘float’ 13,8 / 27,6 / 55,2V
Storage mode 13,2 / 26,4 /52,8V
Charge current house battery (4) 35 / 16 / 9A
Charge current starter battery 1A (12V and 24V models only)
Battery temperature sensor Yes
GENERAL
Programmable relay (5) Yes
Protection (2) a – g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
(RJ45-spliter ASS030065510 needed for 500/800/12ooVA models)
Remote on-off On/off/charger only On/off
DIP switches Yes (6) Yes (3)
Internal DC fuse 150/80/40A
Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
Battery-connection 25 / 16 / 10 mm²
230V AC-connection G-ST18i connector
Weight 6,4 kg
Dimensions (h x w x d) 360 x 240 x 100 mm
STANDARDS
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles ECE R10-5
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for:
general alarm, DC under voltage or generator start/stop signal function
AC rating: 230V/4A
DC rating: 4A up to 35VDC, 1A up to 60VDCMultiplus COMPACT 12/1200/50-16
R16,851.97
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
settings can be changed remotely.Multiplus COMPACT 12/1600/70-16
R17,235.49
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
settings can be changed remotely.Multiplus COMPACT 12/2000/80-30
R21,535.38
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
settings can be changed remotely.Multiplus COMPACT 12/800/35-16
R13,466.76
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
settings can be changed remotely.Multiplus COMPACT 24/1200/25-16
R16,851.63
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
settings can be changed remotely.Multiplus COMPACT 24/1600/40-16
R17,235.49
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
settings can be changed remotely.Multiplus COMPACT 24/2000/50-30
R21,535.38
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
settings can be changed remotely.Multiplus COMPACT 24/800/16-16
R13,466.76
wo AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
discharge the battery, like a water heater for example can be connected to this output (second output available
on models rated at 3 kVA and more).
Virtually unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
Three phase capability
In addition to parallel connection, three units of the same model can be configured for three phase output. But
that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
than 2000 Amps charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist – Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
the capacity of the alternative source. Where peak power is so often required only for a limited period, the
MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
from the battery. When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
minutes with a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
Solar Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
settings can be changed remotely.MultiPlus-II 48/3000/35-50
R22,102.46
A MultiPlus, plus ESS (Energy Storage System) functionality
The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
currentsensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
PowerControl and PowerAssist – Boosting the capacity of the grid or a generator
A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
compatible with both solar charger controllers and grid-tie inverters.
Two AC Outputs
The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel and three phase operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
25 kW / 30 kVA output power with 420 Amps charging capacity.
In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
capacity.
On-site system configuring, monitoring and control
Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
needed).
Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer,
Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
Remote configuring and monitoring
Install a Color Control GX or other GX product to connect to the internet.
Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
When connected to the internet, systems can be accessed remotely, and settings can be changed.MultiPlus-II 48/5000/70-100
R32,769.84
A MultiPlus, plus ESS (Energy Storage System) functionality
The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
currentsensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
PowerControl and PowerAssist – Boosting the capacity of the grid or a generator
A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
compatible with both solar charger controllers and grid-tie inverters.
Two AC Outputs
The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel and three phase operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
25 kW / 30 kVA output power with 420 Amps charging capacity.
In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
capacity.
On-site system configuring, monitoring and control
Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
needed).
Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer,
Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
Remote configuring and monitoring
Install a Color Control GX or other GX product to connect to the internet.
Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
When connected to the internet, systems can be accessed remotely, and settings can be changed.MultiPlus-II 48/5000/70-50
R29,494.49
A MultiPlus, plus ESS (Energy Storage System) functionality
The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
currentsensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
PowerControl and PowerAssist – Boosting the capacity of the grid or a generator
A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
compatible with both solar charger controllers and grid-tie inverters.
Two AC Outputs
The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel and three phase operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
25 kW / 30 kVA output power with 420 Amps charging capacity.
In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
capacity.
On-site system configuring, monitoring and control
Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
needed).
Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer,
Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
Remote configuring and monitoring
Install a Color Control GX or other GX product to connect to the internet.
Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
When connected to the internet, systems can be accessed remotely, and settings can be changed.Phoenix 12/1200 ve.direct schuko
R6,751.32
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 12/250 ve.direct schuko
R1,756.42
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 12/375 ve.direct schuko
R2,269.17
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 12/500 ve.direct schuko
R2,817.82
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 12/800 ve.direct schuko
R5,122.86
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 24/1200 ve.direct schuko
R6,751.32
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 24/250 ve.direct schuko
R1,756.42
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 24/375 ve.direct schuko
R2,269.17
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 24/500 ve.direct schuko
R2,817.82
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 24/800 ve.direct schuko
R5,122.86
Cont. power at 25 degree celcius(1): 800VA
Cont. power at 25/40 degree celcuis: 650/560W
Peak power: 1500W
Output AC voltage/frequency(adjustable): 230VAC or 120VAC +/-3% 50Hz or 60Hz +-.01%
Input voltage range: 9,2-17/18,4-34,0/36,8-62,0V
DC low shut down(adjustable): 9,3/18,6/37,2V
Dynamic(load dependant) DC low shut down(fully configurable): https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff
DC low restart and alarm(adjustable): 10,9/21,8/43,6V
Battery charged detect(adjustable): 14,0/28,0/56,0V
Max efficiency: 90/90/91%
Zero-load power: 6,5/7/9,5W
Default zero-load power in ECO mode(default retry interval:2,5s,adjustable: 1/1,5/3,0W
ECO mode stop and start power setting: Adjustable
Protection(2): a-f
Operating temperature range: -40 to +65 degree celcius(fan assisted cooling) Derate 1,25% per degree celcuis above 40 degree celsius
Humidity(non-condensing) max 95%
Enclosure:
Material & Colour: Steel chassis and plastic cover (blue Ral 5012)
Battery-connection: Screw terminals
Maximuim cable cross section: 10mm2 / AWG8
Standard AC outlets: 230V: Schuko(CEE 7/4). IEC-320(male plug included) UK(BS 1363), AU/NZ (AS/NZS 3112) 120V:Nema 5-15R
Protection category: IP21
Weight: 5,5kg/5,12lbs
Dimensions(mm) 105x216x305
Accessries:
Remote on-off: Yes
Automatic transfer switch: Filax
Standards:
Safety: EN-IEC 60335-1 / EN-IEC 62109-1
EMC: EN 55014-1/ EN55014-2 / IEC6100-6-1 / IEC6100-6-2 / IEC6100-6-3
Automatic Directive: ECE R10-4
- Nonlinear load, crest factor 3:1
- Protection key:
- a) output short circuit
- b) overload
- c) battery voltage too high
- d) battery voltage too low
- e) temperature too high
- f) DC ripple too high
Phoenix 48/1200 ve.direct schuko
R8,050.21
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 48/250 ve.direct schuko
R2,049.14
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 48/375 ve.direct schuko
R2,561.92
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 48/500 ve.direct schuko
R3,696.02
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix 48/800 ve.direct schuko
R5,489.27
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK AU/NZ IEC-320 Nema 5-15R
(male plug included)
DC connection with screw terminals
No special tools needed for installationPhoenix Inverter 48/3000
R20,346.04
SinusMax – Superior engineering
Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
The design criteria have been to produce a true sine wave inverter with optimised efficiency but without
compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
dimensions, light in weight and capable of supplying power, problem-free, to any load.Extra start-up power
A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
technology does not offer such extreme performance. Phoenix inverters, however, are well suited to power up
difficult loads such as refrigeration compressors, electric motors and similar appliances.Virtually unlimited power thanks to parallel and 3-phase operation capability
Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.To transfer the load to another AC source: the automatic transfer switch
If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
other electronic equipment will continue to operate without disruption because the MultiPlus features a very
short switchover time (less than 20 milliseconds).Computer interface
All models have a RS-485 port. All you need to connect to your PC is our MK2 interface (see under accessories).
This interface takes care of galvanic isolation between the inverter and the computer, and converts from RS-485
to RS-232. A RS-232 to USB conversion cable is also available. Together with our VEConfigure software, which
can be downloaded free of charge from our website, all parameters of the inverters can be customised. This
includes output voltage and frequency, over and under voltage settings and programming the relay. This relay
can for example be used to signal several alarm conditions, or to start a generator. The inverters can also be
connected to VENet, the new power control network of Victron Energy, or to other computerised monitoring
and control systems.New applications of high power inverters
The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
calculations please refer to our book “Energy Unlimited” (available free of charge from Victron Energy and
downloadable from www.victronenergy.comPhoenix Inverter 48/5000
R28,817.91
SinusMax – Superior engineering
Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
The design criteria have been to produce a true sine wave inverter with optimised efficiency but without
compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
dimensions, light in weight and capable of supplying power, problem-free, to any load.Extra start-up power
A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
technology does not offer such extreme performance. Phoenix inverters, however, are well suited to power up
difficult loads such as refrigeration compressors, electric motors and similar appliances.Virtually unlimited power thanks to parallel and 3-phase operation capability
Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.To transfer the load to another AC source: the automatic transfer switch
If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
other electronic equipment will continue to operate without disruption because the MultiPlus features a very
short switchover time (less than 20 milliseconds).Computer interface
All models have a RS-485 port. All you need to connect to your PC is our MK2 interface (see under accessories).
This interface takes care of galvanic isolation between the inverter and the computer, and converts from RS-485
to RS-232. A RS-232 to USB conversion cable is also available. Together with our VEConfigure software, which
can be downloaded free of charge from our website, all parameters of the inverters can be customised. This
includes output voltage and frequency, over and under voltage settings and programming the relay. This relay
can for example be used to signal several alarm conditions, or to start a generator. The inverters can also be
connected to VENet, the new power control network of Victron Energy, or to other computerised monitoring
and control systems.New applications of high power inverters
The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
calculations please refer to our book “Energy Unlimited” (available free of charge from Victron Energy and
downloadable from www.victronenergy.comQuattro 12/3000/120-50/50
R40,436.17
Two AC inputs with integrated transfer switch
The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
the battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel operation
Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
power and 840 Amps charging capacity.
Split phase options
Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30kW / 36kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
Three phase capability
Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
being overloaded.
PowerAssist – Boosting shore or generator power
This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
be changed remotelyQuattro 12/5000/220-100/100
R62,977.74
Two AC inputs with integrated transfer switch
The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
the battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel operation
Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
power and 840 Amps charging capacity.
Split phase options
Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30kW / 36kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
Three phase capability
Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
being overloaded.
PowerAssist – Boosting shore or generator power
This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
be changed remotelyQuattro 24/3000/70-50/50
R38,423.87
Two AC inputs with integrated transfer switch
The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
the battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel operation
Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
power and 840 Amps charging capacity.
Split phase options
Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
phase, to supply up to 30kW / 36kVA of split phase power.
Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
Three phase capability
Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
PowerControl – Dealing with limited generator, shore side or grid power
The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
being overloaded.
PowerAssist – Boosting shore or generator power
This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.
System configuring
– In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
a DIP switch setting procedure.
– Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
Configurator software.
– Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
Chargers can be configured with Assistants (dedicated software for specific applications).
On-site Monitoring and control
Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
tablet (Bluetooth Smart), laptop or computer (USB or RS232).
Remote Monitoring and control
Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
be changed remotely