Victron Products

  • BlueSolar PWM-Pro to USB interface cable

    R220.05

    With the BlueSolar PWM-Pro to USB interface cable you can connect the BlueSolar PWM-Pro to your computer.

    View product
  • EasySolar 12/1600/70-16 MPPT 100/50

    R25,249.81

    All-in-one solar power solution
    The EasySolar combines a MPPT solar charge controller, an inverter/charger and AC distribution in
    one enclosure.
    The product is easy to install, with a minimum of wiring.
    The solar charge controller: Blue Solar MPPT 100/50
    Up to three strings of PV panels can be connected to three sets of MC4 (PV-ST01) PV connectors.
    The inverter/charger: MultiPlus Compact 12/1600/70 or 24/1600/40
    The MPPT charge controller and the MultiPlus Compact inverter/charger share the DC battery
    cables (included). The batteries can be charged with solar power (BlueSolar MPPT) and/or with AC
    power (inverter/charger) from the utility grid or a genset.
    AC distribution
    The AC distribution consists of a RCD (30 mA/16 A) and four AC outputs protected by two 10A and
    two 16A circuit breakers.
    One 16A output is controlled by the AC input: it will switch on only when AC is available.
    PowerAssist
    Unique PowerAssist technology protects the utility or generator supply from being overloaded by
    adding extra inverter power when needed

    View product
  • EasySolar 24/1600/40-16 MPPT 100/50

    R25,250.12

    All-in-one solar power solution
    The EasySolar combines a MPPT solar charge controller, an inverter/charger and AC distribution in
    one enclosure.
    The product is easy to install, with a minimum of wiring.
    The solar charge controller: Blue Solar MPPT 100/50
    Up to three strings of PV panels can be connected to three sets of MC4 (PV-ST01) PV connectors.
    The inverter/charger: MultiPlus Compact 12/1600/70 or 24/1600/40
    The MPPT charge controller and the MultiPlus Compact inverter/charger share the DC battery
    cables (included). The batteries can be charged with solar power (BlueSolar MPPT) and/or with AC
    power (inverter/charger) from the utility grid or a genset.
    AC distribution
    The AC distribution consists of a RCD (30 mA/16 A) and four AC outputs protected by two 10A and
    two 16A circuit breakers.
    One 16A output is controlled by the AC input: it will switch on only when AC is available.
    PowerAssist
    Unique PowerAssist technology protects the utility or generator supply from being overloaded by
    adding extra inverter power when needed

    View product
  • EasySolar 24/3000/70 MPPT 150/70 Color Control

    R37,051.32

    The all-in-one solar power solution
    The EasySolar combines a MPPT solar charge controller, an inverter/charger and AC distribution
    in one enclosure.
    The product is easy to install, with a minimum of wiring.
    Color Control panel
    Two outstanding functions:
    – Prioritizes battery charging by the MPPT charge controller
    – Connects to the internet, enabling remote monitoring (VRM website) and remote control.
    AC distribution
    The AC distribution consists of a RCD (30mA / 63A) and four AC outputs protected by two 10A
    and two 16A circuit breakers.
    An additional 16A output is controlled by the AC input: it will switch on only when AC is available.
    PowerAssist
    Unique PowerAssist technology protects the utility or generator supply from being overloaded
    by adding extra inverter power when needed

    View product
  • EasySolar 48/5000/70 MPPT 150/100 Color Control

    R59,831.30

    The all-in-one solar power solution
    The EasySolar combines a MPPT solar charge controller, an inverter/charger and AC distribution
    in one enclosure.
    The product is easy to install, with a minimum of wiring.
    Color Control panel
    Two outstanding functions:
    – Prioritizes battery charging by the MPPT charge controller
    – Connects to the internet, enabling remote monitoring (VRM website) and remote control.
    AC distribution
    The AC distribution consists of a RCD (30mA / 63A) and four AC outputs protected by two 10A
    and two 16A circuit breakers.
    An additional 16A output is controlled by the AC input: it will switch on only when AC is available.
    PowerAssist
    Unique PowerAssist technology protects the utility or generator supply from being overloaded
    by adding extra inverter power when needed

    View product
  • Multiplus 12/1200/50-16

    R12,990.84

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Multiplus 12/3000/120-50

    R28,725.83

    Multiplus, Multifunctional, with intelligent power management

    The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.

    Two AC Outputs

    The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).

    Virtually unlimited power thanks to parallel operation

    Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.

    Three phase capability

    In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.

    Split phase options

    Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.

    PowerControl – Dealing with limited generator, shoreside or grid power

    The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

    PowerAssist – Boosting the capacity of shore or generator power

    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

    Four stage adaptive charger and dual bank battery charging

    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.

    System configuring has never been easier

    After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.

    View product
  • Multiplus 12/3000/120/16

    R26,603.97

    Multifunctional, with intelligent power management
    The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge
    technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the
    MultiPlus has several advanced features, as outlined below.
    Two AC Outputs
    The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of
    a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the
    battery, like a water heater for example, can be connected to this output (second output available on models rated at
    3kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide
    15kW / 18kVA output power with 420 Amps of charging capacity.
    Three phase capability
    In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three
    strings of six parallel units a 45 kW / 54 kVA three phase inverter and 1260 A charger can be built.
    Split phase options
    Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per
    phase, to supply up to 30 kW / 36 kVA of split phase power.
    Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
    www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
    supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore
    current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus
    preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the
    capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will
    make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When
    the load reduces, the spare power is used to recharge the battery.
    Four stage adaptive charger and dual bank battery charging
    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software.
    The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage
    for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger
    datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second
    battery using an independent trickle charge output intended for a main engine or generator starter battery.
    System configuring has never been easier
    After installation, the MultiPlus is ready to go.
    If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even
    parallel and 3-phase operation can be programmed with DIP switches: no computer needed!
    Alternatively, VE.Net can be used instead of the DIP switches.
    And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several
    new, advanced, features

    View product
  • Multiplus 12/500/20-16

    R7,501.58

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Multiplus 12/800/35-16

    R9,313.24

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Multiplus 24/1200/25-16

    R12,990.84

    PowerControl / PowerAssist Yes
    Three Phase and parallel operation Yes
    Transfer switch 16A
    INVERTER
    Input voltage range 9,5 – 17V 19 – 33V 38– 66V
    Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
    Cont. output power at 25°C (3) 1200VA
    Cont. output power at 25°C 1000W
    Cont. output power at 40°C 900W
    Cont. output power at 65°C 600W
    Peak power 2400W
    Maximum efficiency 93 / 94 / 95%
    Zero-load power 10 / 9 / 10W
    Zero-load power in search mode 3/ 3 / 3W
    CHARGER
    AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
    Charge voltage ‘absorption’ 14,4 / 28,8 / 57,6V
    Charge voltage ‘float’ 13,8 / 27,6 / 55,2V
    Storage mode 13,2 / 26,4 /52,8V
    Charge current house battery (4) 50 / 25 / 13A
    Charge current starter battery 1A (12V and 24V models only)
    Battery temperature sensor Yes
    GENERAL
    Programmable relay (5) Yes
    Protection (2) a – g
    VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
    (RJ45-spliter ASS030065510 needed for 500/800/12ooVA models)
    Remote on-off On/off/charger only On/off
    DIP switches Yes (6) Yes (3)
    Internal DC fuse 200/100/50A
    Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
    Humidity (non-condensing): max 95%
    ENCLOSURE
    Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
    Battery-connection 35 / 25 / 10 mm²
    230V AC-connection G-ST18i connector
    Weight 8,2 kg
    Dimensions (h x w x d) 406 x 250 x 100 mm
    STANDARDS
    Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
    Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
    IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
    Road vehicles ECE R10-5
    1) Can be adjusted to 60Hz and to 240V
    2) Protection
    a. Output short circuit
    b. Overload
    c. Battery voltage too high
    d. Battery voltage too low
    e. Temperature too high
    f. 230VAC on inverter output
    g. Input voltage ripple too high
    3) Non-linear load, crest factor 3:1
    4) At 25°C ambient
    5) Programmable relay which can be set for:
    general alarm, DC under voltage or generator start/stop signal function
    AC rating: 230V/4A
    DC rating: 4A up to 35VDC, 1A up to 60VDC

    View product
  • Multiplus 24/3000/70-16

    R26,603.97

    Multiplus, Multifunctional, with intelligent power management

    The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.

    Two AC Outputs

    The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).

    Virtually unlimited power thanks to parallel operation

    Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.

    Three phase capability

    In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.

    Split phase options

    Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.

    PowerControl – Dealing with limited generator, shoreside or grid power

    The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

    PowerAssist – Boosting the capacity of shore or generator power

    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

    Four stage adaptive charger and dual bank battery charging

    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.

    System configuring has never been easier

    After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.

    View product
  • Multiplus 24/3000/70-50

    R28,725.83

    Multiplus, Multifunctional, with intelligent power management

    The Victron MultiPlus Inverter Charger is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next, to these primary functions, the MultiPlus has several advanced features, as outlined below.

    Two AC Outputs

    The main output has no-break functionality. The Victron MultiPlus Inverter Charger takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (second output available on models rated at 3kVA and more).

    Virtually unlimited power thanks to parallel operation

    Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.

    Three phase capability

    In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three-phase inverter and 1260 A charger can be built.

    Split phase options

    Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.

    PowerControl – Dealing with limited generator, shoreside or grid power

    The Victron MultiPlus is a very powerful battery charger. It will, therefore, draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

    PowerAssist – Boosting the capacity of shore or generator power

    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

    Four stage adaptive charger and dual bank battery charging

    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the Victron MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.

    System configuring has never been easier

    After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features.

    View product
  • Multiplus 24/500/10-16

    R7,501.58

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Multiplus 24/5000/120-100

    R42,558.99

    Multifunctional, with intelligent power management
    The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge
    technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the
    MultiPlus has several advanced features, as outlined below.
    Two AC Outputs
    The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of
    a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the
    battery, like a water heater for example, can be connected to this output (second output available on models rated at
    3kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide
    15kW / 18kVA output power with 420 Amps of charging capacity.
    Three phase capability
    In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three
    strings of six parallel units a 45 kW / 54 kVA three phase inverter and 1260 A charger can be built.
    Split phase options
    Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per
    phase, to supply up to 30 kW / 36 kVA of split phase power.
    Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
    www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
    supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore
    current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus
    preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the
    capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will
    make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When
    the load reduces, the spare power is used to recharge the battery.
    Four stage adaptive charger and dual bank battery charging
    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software.
    The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage
    for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger
    datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second
    battery using an independent trickle charge output intended for a main engine or generator starter battery.
    System configuring has never been easier
    After installation, the MultiPlus is ready to go.
    If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even
    parallel and 3-phase operation can be programmed with DIP switches: no computer needed!
    Alternatively, VE.Net can be used instead of the DIP switches.
    And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several
    new, advanced, features

    View product
  • Multiplus 24/800/16-16

    R9,014.24

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Multiplus 48/3000/35-16

    R21,553.82

    Multifunctional, with intelligent power management
    The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge
    technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the
    MultiPlus has several advanced features, as outlined below.
    Two AC Outputs
    The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of
    a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the
    battery, like a water heater for example, can be connected to this output (second output available on models rated at
    3kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide
    15kW / 18kVA output power with 420 Amps of charging capacity.
    Three phase capability
    In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three
    strings of six parallel units a 45 kW / 54 kVA three phase inverter and 1260 A charger can be built.
    Split phase options
    Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per
    phase, to supply up to 30 kW / 36 kVA of split phase power.
    Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
    www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
    supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore
    current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus
    preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the
    capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will
    make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When
    the load reduces, the spare power is used to recharge the battery.
    Four stage adaptive charger and dual bank battery charging
    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software.
    The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage
    for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger
    datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second
    battery using an independent trickle charge output intended for a main engine or generator starter battery.
    System configuring has never been easier
    After installation, the MultiPlus is ready to go.
    If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even
    parallel and 3-phase operation can be programmed with DIP switches: no computer needed!
    Alternatively, VE.Net can be used instead of the DIP switches.
    And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several
    new, advanced, features

    View product
  • Multiplus 48/500/6-16

    R7,195.27

    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
    PowerControl – Dealing with limited generator, shore side or grid power
    With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever
    is extra for charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately
    compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
    High start-up power
    Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
    Search Mode
    When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when
    operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current
    exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
    Programmable relay
    By default, the programmable relay is set as
    an alarm relay, i.e. the relay will de-energise
    in the event of an alarm or a pre-alarm
    (inverter almost too hot, ripple on the input
    almost too high, battery voltage almost too
    low).
    Remote on / off / charger on
    Three pole connect

    View product
  • Multiplus 48/800/9-16

    R9,807.59

    PowerControl / PowerAssist Yes
    Three Phase and parallel operation Yes
    Transfer switch 16A
    INVERTER
    Input voltage range 9,5 – 17V 19 – 33V 38– 66V
    Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
    Cont. output power at 25°C (3) 800VA
    Cont. output power at 25°C 700W
    Cont. output power at 40°C 650W
    Cont. output power at 65°C 400W
    Peak power 1600W
    Maximum efficiency 92 / 93 / 94%
    Zero-load power 7 / 7 / 8W
    Zero-load power in search mode 2 / 2 / 3W
    CHARGER
    AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
    Charge voltage ‘absorption’ 14,4 / 28,8 / 57,6V
    Charge voltage ‘float’ 13,8 / 27,6 / 55,2V
    Storage mode 13,2 / 26,4 /52,8V
    Charge current house battery (4) 35 / 16 / 9A
    Charge current starter battery 1A (12V and 24V models only)
    Battery temperature sensor Yes
    GENERAL
    Programmable relay (5) Yes
    Protection (2) a – g
    VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
    (RJ45-spliter ASS030065510 needed for 500/800/12ooVA models)
    Remote on-off On/off/charger only On/off
    DIP switches Yes (6) Yes (3)
    Internal DC fuse 150/80/40A
    Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
    Humidity (non-condensing): max 95%
    ENCLOSURE
    Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
    Battery-connection 25 / 16 / 10 mm²
    230V AC-connection G-ST18i connector
    Weight 6,4 kg
    Dimensions (h x w x d) 360 x 240 x 100 mm
    STANDARDS
    Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
    Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
    IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
    Road vehicles ECE R10-5
    1) Can be adjusted to 60Hz and to 240V
    2) Protection
    a. Output short circuit
    b. Overload
    c. Battery voltage too high
    d. Battery voltage too low
    e. Temperature too high
    f. 230VAC on inverter output
    g. Input voltage ripple too high
    3) Non-linear load, crest factor 3:1
    4) At 25°C ambient
    5) Programmable relay which can be set for:
    general alarm, DC under voltage or generator start/stop signal function
    AC rating: 230V/4A
    DC rating: 4A up to 35VDC, 1A up to 60VDC

    View product
  • Multiplus COMPACT 12/1200/50-16

    R16,851.97

    Two AC Outputs
    The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
    event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
    20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
    discharge the battery, like a water heater for example can be connected to this output (second output available
    on models rated at 3 kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
    provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
    Three phase capability
    In addition to parallel connection, three units of the same model can be configured for three phase output. But
    that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
    than 2000 Amps charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
    shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
    or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
    charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
    the capacity of the alternative source. Where peak power is so often required only for a limited period, the
    MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
    from the battery. When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
    minutes with a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
    Solar Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
    smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
    settings can be changed remotely.

    View product
  • Multiplus COMPACT 12/1600/70-16

    R17,235.49

    Two AC Outputs
    The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
    event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
    20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
    discharge the battery, like a water heater for example can be connected to this output (second output available
    on models rated at 3 kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
    provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
    Three phase capability
    In addition to parallel connection, three units of the same model can be configured for three phase output. But
    that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
    than 2000 Amps charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
    shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
    or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
    charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
    the capacity of the alternative source. Where peak power is so often required only for a limited period, the
    MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
    from the battery. When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
    minutes with a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
    Solar Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
    smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
    settings can be changed remotely.

    View product
  • Multiplus COMPACT 12/2000/80-30

    R21,535.38

    Two AC Outputs
    The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
    event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
    20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
    discharge the battery, like a water heater for example can be connected to this output (second output available
    on models rated at 3 kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
    provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
    Three phase capability
    In addition to parallel connection, three units of the same model can be configured for three phase output. But
    that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
    than 2000 Amps charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
    shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
    or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
    charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
    the capacity of the alternative source. Where peak power is so often required only for a limited period, the
    MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
    from the battery. When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
    minutes with a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
    Solar Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
    smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
    settings can be changed remotely.

    View product
  • Multiplus COMPACT 12/800/35-16

    R13,466.76

    Two AC Outputs
    The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
    event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
    20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
    discharge the battery, like a water heater for example can be connected to this output (second output available
    on models rated at 3 kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
    provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
    Three phase capability
    In addition to parallel connection, three units of the same model can be configured for three phase output. But
    that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
    than 2000 Amps charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
    shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
    or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
    charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
    the capacity of the alternative source. Where peak power is so often required only for a limited period, the
    MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
    from the battery. When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
    minutes with a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
    Solar Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
    smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
    settings can be changed remotely.

    View product
  • Multiplus COMPACT 24/1200/25-16

    R16,851.63

    Two AC Outputs
    The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
    event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
    20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
    discharge the battery, like a water heater for example can be connected to this output (second output available
    on models rated at 3 kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
    provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
    Three phase capability
    In addition to parallel connection, three units of the same model can be configured for three phase output. But
    that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
    than 2000 Amps charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
    shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
    or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
    charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
    the capacity of the alternative source. Where peak power is so often required only for a limited period, the
    MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
    from the battery. When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
    minutes with a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
    Solar Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
    smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
    settings can be changed remotely.

    View product
  • Multiplus COMPACT 24/1600/40-16

    R17,235.49

    Two AC Outputs
    The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
    event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
    20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
    discharge the battery, like a water heater for example can be connected to this output (second output available
    on models rated at 3 kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
    provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
    Three phase capability
    In addition to parallel connection, three units of the same model can be configured for three phase output. But
    that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
    than 2000 Amps charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
    shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
    or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
    charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
    the capacity of the alternative source. Where peak power is so often required only for a limited period, the
    MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
    from the battery. When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
    minutes with a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
    Solar Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
    smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
    settings can be changed remotely.

    View product
  • Multiplus COMPACT 24/2000/50-30

    R21,535.38

    Two AC Outputs
    The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
    event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
    20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
    discharge the battery, like a water heater for example can be connected to this output (second output available
    on models rated at 3 kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
    provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
    Three phase capability
    In addition to parallel connection, three units of the same model can be configured for three phase output. But
    that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
    than 2000 Amps charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
    shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
    or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
    charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
    the capacity of the alternative source. Where peak power is so often required only for a limited period, the
    MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
    from the battery. When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
    minutes with a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
    Solar Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
    smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
    settings can be changed remotely.

    View product
  • Multiplus COMPACT 24/800/16-16

    R13,466.76

    wo AC Outputs
    The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the
    event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than
    20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus. Loads that should not
    discharge the battery, like a water heater for example can be connected to this output (second output available
    on models rated at 3 kVA and more).
    Virtually unlimited power thanks to parallel operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will
    provide 25 kW / 30 kVA output power with 720 Amps charging capacity.
    Three phase capability
    In addition to parallel connection, three units of the same model can be configured for three phase output. But
    that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more
    than 2000 Amps charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or
    shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator
    or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for
    charging, thus preventing the generator or shore supply from being overloaded.
    PowerAssist – Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement
    the capacity of the alternative source. Where peak power is so often required only for a limited period, the
    MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power
    from the battery. When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of
    minutes with a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT
    Solar Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices,
    smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and
    settings can be changed remotely.

    View product
  • MultiPlus-II 48/3000/35-50

    R22,102.46

    A MultiPlus, plus ESS (Energy Storage System) functionality
    The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
    currentsensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
    The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
    It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
    Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
    PowerControl and PowerAssist – Boosting the capacity of the grid or a generator
    A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
    whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
    function).
    PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
    limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
    When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
    compatible with both solar charger controllers and grid-tie inverters.
    Two AC Outputs
    The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
    a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
    battery, like a water heater for example, can be connected to this output.
    Virtually unlimited power thanks to parallel and three phase operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
    25 kW / 30 kVA output power with 420 Amps charging capacity.
    In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
    all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
    capacity.
    On-site system configuring, monitoring and control
    Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
    needed).
    Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer,
    Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
    Remote configuring and monitoring
    Install a Color Control GX or other GX product to connect to the internet.
    Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    When connected to the internet, systems can be accessed remotely, and settings can be changed.

    View product
  • MultiPlus-II 48/5000/70-100

    R32,769.84

    A MultiPlus, plus ESS (Energy Storage System) functionality
    The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
    currentsensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
    The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
    It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
    Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
    PowerControl and PowerAssist – Boosting the capacity of the grid or a generator
    A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
    whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
    function).
    PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
    limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
    When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
    compatible with both solar charger controllers and grid-tie inverters.
    Two AC Outputs
    The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
    a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
    battery, like a water heater for example, can be connected to this output.
    Virtually unlimited power thanks to parallel and three phase operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
    25 kW / 30 kVA output power with 420 Amps charging capacity.
    In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
    all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
    capacity.
    On-site system configuring, monitoring and control
    Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
    needed).
    Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer,
    Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
    Remote configuring and monitoring
    Install a Color Control GX or other GX product to connect to the internet.
    Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    When connected to the internet, systems can be accessed remotely, and settings can be changed.

    View product
  • MultiPlus-II 48/5000/70-50

    R29,494.49

    A MultiPlus, plus ESS (Energy Storage System) functionality
    The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
    currentsensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
    The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
    It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
    Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
    PowerControl and PowerAssist – Boosting the capacity of the grid or a generator
    A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
    whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
    function).
    PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
    limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
    When the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
    compatible with both solar charger controllers and grid-tie inverters.
    Two AC Outputs
    The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
    a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
    battery, like a water heater for example, can be connected to this output.
    Virtually unlimited power thanks to parallel and three phase operation
    Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
    25 kW / 30 kVA output power with 420 Amps charging capacity.
    In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
    all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
    capacity.
    On-site system configuring, monitoring and control
    Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
    needed).
    Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer,
    Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
    Remote configuring and monitoring
    Install a Color Control GX or other GX product to connect to the internet.
    Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    When connected to the internet, systems can be accessed remotely, and settings can be changed.

    View product
  • Phoenix 12/1200 ve.direct schuko

    R6,751.32

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 12/250 ve.direct schuko

    R1,756.42

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 12/375 ve.direct schuko

    R2,269.17

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 12/500 ve.direct schuko

    R2,817.82

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 12/800 ve.direct schuko

    R5,122.86

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 24/1200 ve.direct schuko

    R6,751.32

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 24/250 ve.direct schuko

    R1,756.42

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 24/375 ve.direct schuko

    R2,269.17

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 24/500 ve.direct schuko

    R2,817.82

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 24/800 ve.direct schuko

    R5,122.86

    Cont. power at 25 degree celcius(1): 800VA

    Cont. power at 25/40 degree celcuis: 650/560W

    Peak power: 1500W

    Output AC voltage/frequency(adjustable): 230VAC or 120VAC +/-3% 50Hz or 60Hz +-.01%

    Input voltage range: 9,2-17/18,4-34,0/36,8-62,0V

    DC low shut down(adjustable): 9,3/18,6/37,2V

    Dynamic(load dependant) DC low shut down(fully configurable): https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff

    DC low restart and alarm(adjustable): 10,9/21,8/43,6V

    Battery charged detect(adjustable): 14,0/28,0/56,0V

    Max efficiency: 90/90/91%

    Zero-load power: 6,5/7/9,5W

    Default zero-load power in ECO mode(default retry interval:2,5s,adjustable: 1/1,5/3,0W

    ECO mode stop and start power setting: Adjustable

    Protection(2): a-f

    Operating temperature range: -40 to +65 degree celcius(fan assisted cooling) Derate 1,25% per degree celcuis above 40 degree celsius

    Humidity(non-condensing) max 95%

    Enclosure:

    Material & Colour: Steel chassis and plastic cover (blue Ral 5012)

    Battery-connection: Screw terminals

    Maximuim cable cross section: 10mm2 / AWG8

    Standard AC outlets: 230V: Schuko(CEE 7/4). IEC-320(male plug included) UK(BS 1363), AU/NZ (AS/NZS 3112) 120V:Nema 5-15R

    Protection category: IP21

    Weight: 5,5kg/5,12lbs

    Dimensions(mm) 105x216x305

    Accessries:

    Remote on-off: Yes

    Automatic transfer switch: Filax

    Standards:

    Safety: EN-IEC 60335-1 / EN-IEC 62109-1

    EMC: EN 55014-1/ EN55014-2 / IEC6100-6-1 / IEC6100-6-2 / IEC6100-6-3

    Automatic Directive: ECE R10-4

    • Nonlinear load, crest factor 3:1
    • Protection key:
    • a) output short circuit
    • b) overload
    • c) battery voltage too high
    • d) battery voltage too low
    • e) temperature too high
    • f) DC ripple too high
    View product
  • Phoenix 48/1200 ve.direct schuko

    R8,050.21

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 48/250 ve.direct schuko

    R2,049.14

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 48/375 ve.direct schuko

    R2,561.92

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 48/500 ve.direct schuko

    R3,696.02

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix 48/800 ve.direct schuko

    R5,489.27

    VE.Direct communication port
    The VE.Direct port can be connected to:
    • A computer (VE.Direct to USB interface cable needed)
    • Apple and Android smartphones, tablets, MacBook’s and other devices
    (VE.Direct Bluetooth Smart dongle needed)
    Fully configurable:
    • Low battery voltage alarm trip and reset levels
    • Low battery voltage cut-off and restart levels
    • Dynamic cut-off: load dependent cut-off level
    • Output voltage 210 – 245V
    • Frequency 50 Hz or 60 Hz
    • ECO mode on/off and ECO mode sense level
    Monitoring:
    • In- and output voltage, % load and alarms
    Proven reliability
    The full bridge plus toroidal transformer topology has proven its reliability over many years.
    The inverters are short circuit proof and protected against overheating, whether due to overload or
    high ambient temperature.
    High start-up power
    Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
    ECO mode
    When in ECO mode, the inverter will switch to standby when the load decreases below a preset
    value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
    default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
    Remote on/off
    A remote on/off switch can be connected to a two pole connector, or between battery plus and the
    left hand contact of the two pole connector.
    LED diagnosis
    Please see manual for a description.
    To transfer the load to another AC source: the automatic transfer switch
    For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
    a very short switchover time (less than 20 milliseconds) so that computers and other electronic
    equipment will continue to operate without disruption.
    Available with different output sockets
    Schuko UK AU/NZ IEC-320 Nema 5-15R
    (male plug included)
    DC connection with screw terminals
    No special tools needed for installation

    View product
  • Phoenix Inverter 48/3000

    R20,346.04

    SinusMax – Superior engineering
    Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
    The design criteria have been to produce a true sine wave inverter with optimised efficiency but without
    compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
    dimensions, light in weight and capable of supplying power, problem-free, to any load.

    Extra start-up power
    A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
    technology does not offer such extreme performance. Phoenix inverters, however, are well suited to power up
    difficult loads such as refrigeration compressors, electric motors and similar appliances.

    Virtually unlimited power thanks to parallel and 3-phase operation capability
    Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
    will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.

    To transfer the load to another AC source: the automatic transfer switch
    If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
    switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
    other electronic equipment will continue to operate without disruption because the MultiPlus features a very
    short switchover time (less than 20 milliseconds).

    Computer interface
    All models have a RS-485 port. All you need to connect to your PC is our MK2 interface (see under accessories).
    This interface takes care of galvanic isolation between the inverter and the computer, and converts from RS-485
    to RS-232. A RS-232 to USB conversion cable is also available. Together with our VEConfigure software, which
    can be downloaded free of charge from our website, all parameters of the inverters can be customised. This
    includes output voltage and frequency, over and under voltage settings and programming the relay. This relay
    can for example be used to signal several alarm conditions, or to start a generator. The inverters can also be
    connected to VENet, the new power control network of Victron Energy, or to other computerised monitoring
    and control systems.

    New applications of high power inverters
    The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
    calculations please refer to our book “Energy Unlimited” (available free of charge from Victron Energy and
    downloadable from www.victronenergy.com

    View product
  • Phoenix Inverter 48/5000

    R28,817.91

    SinusMax – Superior engineering
    Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications.
    The design criteria have been to produce a true sine wave inverter with optimised efficiency but without
    compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact
    dimensions, light in weight and capable of supplying power, problem-free, to any load.

    Extra start-up power
    A unique feature of the SinusMax technology is very high start-up power. Conventional high frequency
    technology does not offer such extreme performance. Phoenix inverters, however, are well suited to power up
    difficult loads such as refrigeration compressors, electric motors and similar appliances.

    Virtually unlimited power thanks to parallel and 3-phase operation capability
    Up to 6 units inverters can operate in parallel to achieve higher power output. Six 24/5000 units, for example,
    will provide 24kW / 30kVA output power. Operation in 3-phase configuration is also possible.

    To transfer the load to another AC source: the automatic transfer switch
    If an automatic transfer switch is required we recommend using the MultiPlus inverter/charger instead. The
    switch is included in these products and the charger function of the MultiPlus can be disabled. Computers and
    other electronic equipment will continue to operate without disruption because the MultiPlus features a very
    short switchover time (less than 20 milliseconds).

    Computer interface
    All models have a RS-485 port. All you need to connect to your PC is our MK2 interface (see under accessories).
    This interface takes care of galvanic isolation between the inverter and the computer, and converts from RS-485
    to RS-232. A RS-232 to USB conversion cable is also available. Together with our VEConfigure software, which
    can be downloaded free of charge from our website, all parameters of the inverters can be customised. This
    includes output voltage and frequency, over and under voltage settings and programming the relay. This relay
    can for example be used to signal several alarm conditions, or to start a generator. The inverters can also be
    connected to VENet, the new power control network of Victron Energy, or to other computerised monitoring
    and control systems.

    New applications of high power inverters
    The possibilities of paralleled high power inverters are truly amazing. For ideas, examples and battery capacity
    calculations please refer to our book “Energy Unlimited” (available free of charge from Victron Energy and
    downloadable from www.victronenergy.com

    View product
  • Quattro 12/3000/120-50/50

    R40,436.17

    Two AC inputs with integrated transfer switch
    The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
    generators. The Quattro will automatically connect to the active source.
    Two AC Outputs
    The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
    grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
    the battery, like a water heater for example, can be connected to this output.
    Virtually unlimited power thanks to parallel operation
    Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
    power and 840 Amps charging capacity.
    Split phase options
    Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
    phase, to supply up to 30kW / 36kVA of split phase power.
    Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
    www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
    Three phase capability
    Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
    connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
    supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
    account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
    being overloaded.
    PowerAssist – Boosting shore or generator power
    This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
    capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
    make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
    the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
    a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
    Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
    tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
    be changed remotely

    View product
  • Quattro 12/5000/220-100/100

    R62,977.74

    Two AC inputs with integrated transfer switch
    The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
    generators. The Quattro will automatically connect to the active source.
    Two AC Outputs
    The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
    grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
    the battery, like a water heater for example, can be connected to this output.
    Virtually unlimited power thanks to parallel operation
    Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
    power and 840 Amps charging capacity.
    Split phase options
    Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
    phase, to supply up to 30kW / 36kVA of split phase power.
    Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
    www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
    Three phase capability
    Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
    connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
    supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
    account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
    being overloaded.
    PowerAssist – Boosting shore or generator power
    This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
    capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
    make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
    the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
    a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
    Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
    tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
    be changed remotely

    View product
  • Quattro 24/3000/70-50/50

    R38,423.87

    Two AC inputs with integrated transfer switch
    The Quattro can be connected to two independent AC sources, for example the public grid and a generator, or two
    generators. The Quattro will automatically connect to the active source.
    Two AC Outputs
    The main output has no-break functionality. The Quattro takes over the supply to the connected loads in the event of a
    grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
    computers and other electronic equipment will continue to operate without disruption.
    The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge
    the battery, like a water heater for example, can be connected to this output.
    Virtually unlimited power thanks to parallel operation
    Up to 6 Quattro units can operate in parallel. Six units 48/10000/140, for example, will provide 48kW / 60kVA output
    power and 840 Amps charging capacity.
    Split phase options
    Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per
    phase, to supply up to 30kW / 36kVA of split phase power.
    Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on
    www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.
    Three phase capability
    Three units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
    connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.
    PowerControl – Dealing with limited generator, shore side or grid power
    The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
    supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
    account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
    being overloaded.
    PowerAssist – Boosting shore or generator power
    This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
    capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
    make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
    the load reduces, the spare power is used to recharge the battery.
    Solar energy: AC power available even during a grid failure
    The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems.
    Loss of mains detection software is available.
    System configuring
    – In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
    a DIP switch setting procedure.
    – Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
    – Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
    Chargers can be configured with Assistants (dedicated software for specific applications).
    On-site Monitoring and control
    Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
    tablet (Bluetooth Smart), laptop or computer (USB or RS232).
    Remote Monitoring and control
    Color Control GX or other GX devices.
    Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
    Remote configuring
    When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can
    be changed remotely

    View product

Filter by price

Title

Go to Top